39
•
Materials which are often used to make worktops expand on contact with water. To protect
the cut out edge, apply a coat of varnish or special sealant. Particular care must be given
to applying the adhesive joint supplied with the hob to prevent any leakage into the
supporting furniture. This gasket guaranties a correct seal when used in conjunction with
smooth work top surfaces.
•
The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. In case of absence of instructions respect a distance
minimum of 760 mm.
•
The connection cord should be subjected, after building, with no mechanical constraint,
such for example of the fact of the drawer.
•
WARNING: Use only hob guards designed by the manufacturer of the cooking appliance
or indicated by the manufacturer of the appliance in the instructions for use as suitable or
hob guards incorporated in the appliance. The use of inappropriate guards can cause
accidents.
Ventilation
•
Any cross beneath the worktop must be removed if it is located partly or totally into the cut
out area .
•
When building-in the cooktop, make sure not to obstruct the openings foreseen in the
casing of the hob. These holes are necessary for an efficient ventilation of the appliance.
•
Avoid any excessive heating under the cooktop, eg related to a poorly ventilated and/or
insulated oven.
•
If the induction hob is installed over a pyrolytic oven, it cannot be used as long as the
pyrolytic function is activated.
ELECTRICAL CONNECTION
•
The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
•
Protection against the parts under tension must be ensured after the building-in.
•
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
•
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or even.
Summary of Contents for EKI9652.1F
Page 20: ...19828 0...