background image

26 

  If  a  drawer  is  situated  under  the  embedded  appliance,  make 

sure  the  space  between  the  content  of  the  drawer  and  the 
inferior  part  of  the  appliance  is  large  enough  (2  cm).  This  is 
essential to guaranty a correct ventilation.  

  Never  put  any  inflammable  object  (ex.  sprays)  into  the  drawer 

situated  under  the  vitroceramic  hob.  The  eventual  cutlery 
drawers must be resistant to heat.  

Precautions in case of appliance failure 

  If  a  defect  is  noticed,  switch  on  the  appliance  and  turn  off  the 

electrical supplying. 

  If the ceramic glass is cracked or fissured, you must unplug the 

appliance and contact the after sales service. 

  Repairing  has  to  be  done  by  specialists.  Do  not  open  the 

appliance by yourself. 

  WARNING: If the surface is cracked, switch off the appliance to 

avoid the possibility of electric shock. 

  If the supply cor dis damaged, it must be replaced by a cable or 

special  set  available  by  the  manufacturer  or  his  after  sale 
service. 

Other protections 

  Note  sure  that  the  container  pan  is  always  centred  on  the 

cooking  zone.    The  bottom  of  the  pan  must  have  to  cover  as 
much as possible the cooking zone.  

  For the users of pacemaker, the magnetic field could influence 

its operating.  We recommend getting information to the retailer 
or of the doctor.  

  Do not to use aluminium or synthetic material containers:  they 

could melt on still hot cooking zones. 

  NEVER  try  to  extinguish  a  fire  with  water,  but  switch  off  the 

appliance and then cover flame e.g. with a lid or a fire blanket. 

   THE USE OF EITHER POOR QUALITY POT OR ANY 

INDUCTION ADAPTOR PLATE FOR NON-MAGNETIC 

COOKWARE RESULTS IN A WARRANTY BREACH. 

IN THIS CASE, THE MANUFACTURER CANNOT BE 

HELD RESPONSIBLE FOR ANY DAMAGE CAUSED TO 

THE HOB AND/OR ITS ENVIRONMENT. 

Summary of Contents for EKI9652.1F

Page 1: ...BEDIENUNGSANWEISUNG mit Montageanweisungen Instructions for use and installation Instructions d utilisation et d installation EKI9652 1F...

Page 2: ...ROL PANEL 28 USE OF THE APPLIANCE 28 DISPLAY 28 VENTILATION 28 STARTING UP AND APPLIANCE MANAGEMENT 29 BEFORE THE FIRST USE 29 INDUCTION PRINCIPLE 29 SENSITIVE TOUCH 29 STARTING UP 29 PAN DETECTION 30...

Page 3: ...plate can not be used as freestanding or as working surface The appliance must be grounded and connected conforming to local standards Do not use any extension cable to connect it The appliance can n...

Page 4: ...children without supervision Metallic objects such as knives forks spoons and lids should not be placed on the surface since they can get hot Precautions not to damage the appliance Raw pan bottoms o...

Page 5: ...to avoid the possibility of electric shock If the supply cor dis damaged it must be replaced by a cable or special set available by the manufacturer or his after sale service Other protections Note s...

Page 6: ...177 3 Wh kg Middle heating zone 279 mm Minimum detection 110 mm Nominal power 2300 W Booster power 3000 W Standardised cookware category D Energy consumption ECcw 171 6 Wh kg Rear right heating zone...

Page 7: ...ed L Locking Control panel locking II Stop Go The hob is in pause Keep warm Maintain automatically of 70 C Bridge 2 cooking zones are combined Ventilation The cooling system operates continuously He s...

Page 8: ...atically the size of the pan With a too small diameter the pan doesn t work This diameter is varying in function of the heating zone diameter If the pan is not adapted to the induction hob the display...

Page 9: ...em There are risks of burn and fire Booster function The booster function P grants a boost of power to the selected heating zone If this function is activated the heating zones works during 5 minutes...

Page 10: ...y 0 To select Timer Press key during 3s The remaining time To stop the Timer Press key 00 then stops If several timers are activated repeat the process Automatic stop at the end of the cooking time As...

Page 11: ...c cooking Action Control panel Display Zone selection Press key 0 Stop the automatic cooking Press key II 0 9 Bridge This function allows to use 2 cooking zones at same time with the same features as...

Page 12: ...warm function The recall procedure is following Press the key Then press the key II within 6 seconds The precedent settings are activated Keep Warm This function allows to reach and maintain automatic...

Page 13: ...ouble beep Registering validation If no memorising is made within timer validation the electronics returns in cooking position To activate the memory program for a cooking zone Action Control panel Di...

Page 14: ...induction heating zone set at level 9 This water must heat in a few seconds A magnet stucks on the bottom of the pan Certain pans can make noise when they are placed on an induction cooking zone This...

Page 15: ...thoroughly Highly corrosive or abrasive detergents and cleaning equipment likely to cause scratches must be absolutely avoided Do not ever use any steam cleaner or pressure washer Do not use any obje...

Page 16: ...y is released or cleaned The control panel displays E2 or EH The hob is overheated let it cool and then turn it on again The control panel displays E3 The pan is not adapted change the pan The control...

Page 17: ...ace on either side There may be a wall at the rear and tall units or a wall at one side On the other side however no unit or divider must stand higher than the hob The piece of furniture or the suppor...

Page 18: ...re not to obstruct the openings foreseen in the casing of the hob These holes are necessary for an efficient ventilation of the appliance Avoid any excessive heating under the cooktop eg related to a...

Page 19: ...ge between terminal 1 and 2 Attach the earth to the terminate earth the neutral N to terminal 4 the Phase L to one of the terminals 1 or 2 Biphase 400V 2P N Attach the earth to the terminate earth the...

Page 20: ...19828 0...

Reviews: