Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
12) TAPS
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 1).
- Remove knob “M” (fig. 15) of the tap, which is
simply pressed on to its rod.
- Insert a small screwdriver “D” into hole “C” (fig. 15)
and turn the throttle screw to the right or left until
the burner flame has been adequately regulated to
the “Reduced rate” position.
Check that the flame does not go out when the knob
is sharply switched from the “Full on” to the
“Reduced rate” position.
It is understood that only burners operating with
G20 gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with G30 or
G31.
ADJUSTMENTS
FIG. 15
TECHNICAL DATA ON THE DATA LABEL
3 BURNERS (RIGHT UR)
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 6.45 kW
Tot.Nom.H.K.Towngas Rate = 6.75 kW
Tot.Nom.L.P.G. Rate = 469 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
3 BURNERS (LEFT UR)
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 8.45 kW
Tot.Nom.H.K.Towngas Rate = 9.150 kW
Tot.Nom.L.P.G. Rate = 614 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
4 B 1 PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 7.5 kW
Tot.Nom.H.K.Towngas Rate = 7.9 kW
Tot.Nom.L.P.G. Rate = 545 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
Pot.Tot.Nom.El.Rating = 1000 ÷ 1500 W
2 UR BURNERS
LPG= 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 7.4 kW
Tot.Nom.H.K.Towngas Rate = 8 kW
Tot.Nom.L.P.G. Rate = 538 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
5 BURNERS
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 11.2 kW
Tot.Nom.H.K.Towngas Rate = 11.9 kW
Tot.Nom.L.P.G. Rate = 814 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
3 B 1 PLATE
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 5.75 kW
Tot.Nom.H.K.Towngas Rate = 6.150 kW
Tot.Nom.L.P.G. Rate = 418 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
Pot.Tot.Nom.El.Rating = 1000 ÷ 1500 W
4 BURNERS
LPG = 30 mbar
TOWN = 10 mbar
Tot.Nom.L.p.g. Gas Rate = 7.5 kW
Tot.Nom.H.K.Towngas Rate = 7.9 kW
Tot.Nom.L.P.G. Rate = 545 g/h
Voltage = 220 – 230 V~
Frequency = 50 Hz
HONG KONG MARKET
21