background image

16

SERVICING

Always disconnect the appliance from the
electricity and gas mains before proceeding with
any servicing operation.

14) REPLACING HOT PLATE PARTS

When parts housed within the hot plate need
replacing, it is first necessary to remove the hot
plate itself from the cabinet, to overturn it, unscrew
screws “V” and to remove part “T” (see fig. 17).
After having carried out the above listed
operations, the burners (fig. 18), taps (fig. 19) and
electrical components can all be replaced (fig. 20).

NB:

the ignition bar must be removed before

replacing the taps in appliances with automatic
ignition systems.
It is advisable to change seal “D” whenever a tap is
replaced to ensure a perfect tightness.

Greasing the taps (see fig. 21 - 22)

If a tap becomes stiff to operate, it must be
immediately greased in compliance with the
following instructions:
- Remove the tap.
- Clean the cone and its housing using a cloth

soaked in diluent.

- Lightly spread the cone with the relative grease.
- Fit the cone back in place, operate it several times

and then remove it again. Eliminate any excess
grease and check that the gas ducts have not
become clogged.

- Fit all parts back in place, complying with the

demounting order in reverse.

To facilitate the servicing technician’s task, here is a
chart with the types and sections of the powering
cables and the ratings of the electrical components.

FIG. 20

FIG. 21

FIG. 22

FIG. 17

FIG. 18

FIG. 19

17

SERVICING

15) REPLACING THE BATTERY

To change the battery (see fig. 23) comply with 
following instructions:
- Unscrew cap “T” and remove exausty battery.
- Insert a 1,5 V new battery. The positive polarity

“+” is turn over inside.

- Rescrew the cap “T”.
- Re-assembly all the movable parts.

WARNING:
The batteries contain a dangerous material for
our ambient. Always put them in a separate and
safe container.
If you eliminate your appliance, remember to
take off the battery.

FIG. 23

CAUTION

The device should not be operated for more than 15 second.
If after 15 second, the burner has not lit, stop operating the device & open the compartment door
and/or wait at least 1 minutes before attempting a further ignite of the burner.
In the event of the flame being accidentally extinguished, turn off the burner control and do not
attempt to re-ignite the burner for at least 1 minutes.

Summary of Contents for PCFZ 60 N4

Page 1: ...al and on the appliance itself The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures are purely indicative The Manufacturer also reserves the right to make any...

Page 2: ...CE AND SPARE PARTS Before leaving the factory this appliance will have been tested and regulated by expert and specialized personnel in order to guarantee the best performances Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention For this reason always contact your Dealer or our nearest After Sales Service C...

Page 3: ... boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal Burners Power ratings Pans Ø in cm Ultra rapid 3700 4000 24 26 Rapid 3000 3400 20 22 Semirapid 1750 16 18 Auxiliary 1000 10 14 WARNINGS Burners with flame failure device may only beignited when the relative knob has been set to the Full on position lar...

Page 4: ... 230 V Frequency 50 Hz 3 BURNERS LEFT UR LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 8 45 kW Tot Nom L P G Rate 614 g h Voltage 220 230 V Frequency 50 Hz 4 BURNERS 1 PLATE LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 5 kW Tot Nom L P G Rate 545 g h Voltage 220 230 V Frequency 50 Hz Pot Tot Nom El Rating 1000 1500W 2 UR BURNERS LPG 28 30 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 4 kW Tot Nom...

Page 5: ...es To thaw frozen foods and prepare stews heat to boiling point or simmer To heat foods to boiling point To brown delicate meats and fish For escalopes and steaks To simmer large amounts of food To bring large amounts of liquid to the boil For frying FIG 6 28 TECHNICAL DATA ON THE DATA LABEL 3 BURNERS RIGHT UR LPG 30 mbar TOWN 10 mbar Tot Nom L p g Gas Rate 6 1 kW Tot Nom Towngas Rate 5 85kW Tot N...

Page 6: ...ner cap C fig 8 have correctly positioned on the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they are difficult open or close Contact the technical assistance service for repairs Correctly preserve the plate after use by treating it with special products...

Page 7: ...me small openings in the furniture as per fig 9 A and 9 B The cylinder holder compartment must have the following characteristics Resistance to a load No fitment of the cylinder directly on the floor are allowed The cylinder equipped with governor must be set or take off from the compartment in a easy way The cylinder cock must be easily accessible The flexible tube musn t be in contact with sharp...

Page 8: ...he room in which the appliance is installed is permanently ventilated in order to allow the appliance itself to operate correctly the necessary amount of air is that required for regular gas combustion and ventilation of the relative room the volume of which must not be less than 20 m3 Air must naturally flow through permanent openings in the walls of the room in question These openings must vent ...

Page 9: ... verify the gasproof using a soap solution never a flame WARNINGS Remember that the gas inlet union on the appliance is a 1 2 gas parallel male type in compliance with ISO 228 1 standards Installation of stainless steel pipe and rubber hose pipe must ensure that it is never able to touch mobile parts of the built in cabinet eg drawers Furthermore it must not pass through compartments that could be...

Page 10: ...ential circuit breaker You are strongly advised to fix the relative yellow green earth wire to an efficient earthing system WARNINGS All our appliances are designed and manufactured in compliance with European standards EN 60 335 1 and EN 60 335 2 6 plus the relative amendments The appliance complies with the provisions of the following EEC Directives 89 336 92 31 93 68 regarding to electromagneti...

Page 11: ...he edge of the hot plate itself so that the outer side of the seal perfectly matches the outer perimetral edge of the hot plate The ends of the strips must fit together without overlapping Unscrew the ignition cap T see fig 14 and fit a 1 5 V battery not included in the appliance with the positive polarity turn inside Rescrew the cap Evenly and securely fix the seal to the hot plate pressing it in...

Page 12: ... L p g Gas Rate 6 45 kW Tot Nom H K TowngasRate 6 75kW Tot Nom L P G Rate 469 g h Voltage 220 230 V Frequency 50 Hz 3 BURNERS LEFT UR LPG 30 mbar TOWN 10 mbar Tot Nom L p g Gas Rate 8 45 kW Tot Nom H K TowngasRate 9 150kW Tot Nom L P G Rate 614 g h Voltage 220 230 V Frequency 50 Hz 4 BURNERS 1 PLATE LPG 30 mbar TOWN 10 mbar Tot Nom L p g GasRate 7 5kW Tot Nom H K TowngasRate 7 9kW Tot Nom L P G Ra...

Page 13: ... Y 1400 3700 62 LPG 28 30 218 85 750 3000 45 LPG 37 214 85 750 3000 45 NATURAL 20 286 115 Y 750 3000 45 LPG 28 30 127 65 500 1750 35 LPG 37 125 65 500 1750 35 NATURAL 20 167 97 Z 500 1750 35 BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1 100 mm MIN MAX 1 100 mm OTHER MARKETS LPG 28 30 73 50 400 1000 30 LPG 37 71 50 400 1000 30 NATURAL 20...

Page 14: ...ATURAL 20 95 72 X 400 1000 30 TOWN SHANGHAI 10 262 135 11 400 1000 30 TOWN GUANGZHOU 20 128 87 400 1000 30 1 ULTRA RAPID 2 RAPID 3 SEMIRAPID 4 AUXILIARY BY PASS 19 TECHNICAL DATA ON THE DATA LABEL 4 BURNERS 1 PLATE LPG 28 30 mbar LPG 37 mbar NATURAL 20 mbar Tot Nom Gas Rate 7 5 kW Tot Nom L P G Rate 545 g h Voltage 220 230 V Frequency 50 Hz Pot Nom El Rating 1000 1500W 2 UR BURNERS LPG 28 30 mbar ...

Page 15: ...PASS COREA MARKET LPG 28 30 269 93 1400 3700 62 NATURAL 20 352 124 Y 1400 3700 62 LPG 28 30 218 85 750 3000 45 NATURAL 20 287 115 Y 750 3000 45 LPG 28 30 127 65 500 1750 35 NATURAL 20 167 97 Z 500 1750 35 BURNERS N DESCRIPTION GAS NORMAL PRESSURE NORMAL RATE INJECTOR DIAMETER NOMINAL HEAT INPUT W mbar g h l h 1 100 mm MIN MAX 1 100 mm LPG 28 30 73 50 400 1000 30 NATURAL 20 95 72 X 400 1000 30 1 UL...

Page 16: ...ve it again Eliminate any excess grease and check that the gas ducts have not become clogged Fit all parts back in place complying with the demounting order in reverse To facilitate the servicing technician s task here is a chart with the types and sections of the powering cables and the ratings of the electrical components FIG 20 FIG 21 FIG 22 FIG 17 FIG 18 FIG 19 17 SERVICING 15 REPLACING THE BA...

Reviews: