background image

Maintenance and care

GB

23

Opening the hood

Disconnect the hood from the mains or switch off
the fuse!
  

Opening the metal screen

Press

 in the middle of the metal screen, around 30 mm from

the front edge. The lock is released (soft 

CLICK

).

Magnets will keep the metal screen in a horizontal position.

• To open put your hand into the edge suction from the side and

gently pull the metal screen so that it swings open. 

Closing the metal screen

• Swing the metal screen upwards until the magnets hold it in a

horizontal position.

• Then press onto the same point used for removing the metal

screen so that the lock engages again (soft 

CLICK

).

To ensure that the metal screen has engaged properly, put
your hand into the edge suction from the side and pull gently;
the metal screen must remain at the top. 

Removing the metal screen

The metal screen can be removed to clean it. It must hang
downwards to remove it; the hood is open.

Caution – it could fall onto the hob, so please hold it firmly!
Protect the hob located below the hood with a thick blanket!

• To remove the metal screen, hold it and press the bolt on the

bearing inwards; this will release the metal screen on one side.
It can then easily be removed on the other side.

• Proceed in reverse order to replace the metal screen.

Cleaning the inside of the hood

Pull out the power plug or disconnect the fuse!
The metal screen must be removed for cleaning pur-
poses!

Deposits on easily accessible areas on the inside of the hood can
be wiped away carefully with a damp cloth and some detergent.

Please always work carefully as there is a risk of sharp
edges causing injury.

Clean the outer surface of the motor as well.

Ensure that no moisture gets into electrical parts.

Metal screen

press bolt

Summary of Contents for KD 12660.0GE

Page 1: ...use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 9660 0GE KDUM 9660 0GE KD 12660 0GE KDUM 12660 0GE ...

Page 2: ...ur appliance so that it will provide you with many years of reliable service Should your appliance develop a fault please first consult the section on What to do if trouble occurs You can often rectify minor problems yourself without having to call in a service engi neer Please keep this manual in a safe place and pass it on to new owners for their information and safety Contents Safety instructio...

Page 3: ...e The air outlets may not be covered during recirculation air operation in order to enable the air to escape freely The hood may not be cleaned with a steam cleaner since safety can no longer be guaranteed due to the steam Do not look into the intensive source of light for too long It is absolutely essential to observe maintenance and cleaning cycles as failure to do so results in a risk of fire a...

Page 4: ...ance description 1 Chimney top 2 Chimney bottom 3 Canopy 4 Glass canopy safety glass 5 Control elements 6 Metal grease filters both sides 2 filters 7 LED lamp 8 Metal screen 9 Metal grease filter 10 Pressure point for opening see p 23 ...

Page 5: ...will immediately select fan setting 4 using the Plus key will select the first fan setting The fan setting is shown by the lighting up of 4 LEDs in the dis play Switching off the fan If the Plus key is pressed when the fan setting is at 4 the hood will be switched off If the Minus key is pressed when the fan setting is at 1 the hood will also be switched off LED lamp Pressing the Lamp button will ...

Page 6: ... To cancel see the section Saturation display The charcoal filter must be replaced sooner when the hood is used more frequently and odours are not sufficiently reduced The metal filter should be cleaned in good time and the charcoal filter replaced in particular in the case of recirculation air operation in order to avoid undesirable deposits of greasy vapours and condensate on kitchen units Besid...

Page 7: ...een must remain at the top Removing the metal screen The metal screen can be removed to clean it It must hang downwards to remove it the hood is open Caution it could fall onto the hob so please hold it firmly Protect the hob located below the hood with a thick blanket To remove the metal screen hold it and press the bolt on the bearing inwards this will release the metal screen on one side It can...

Page 8: ...at it can be optimally cleaned An intensive programme at 65 C if possible should be selected in order to fully remove deposits of fat Restore the mains power supply Replacing the charcoal filters recirculation air operation only The charcoal filter is located directly behind the metal grease filter The metal grease filter will need to be removed in order to replace the charcoal filter Put the char...

Page 9: ... it see previous section Remove the screws with a screw driver Remove the coloured plugs This can be done carefully with your finger nail or a kitchen knife The light covering plastic and the metal screen will come lose right across Caution it could fall onto the hob so please hold it firmly Remove the metal grease filter possibly with the charcoal filter The plug contacts for the LED strip will b...

Page 10: ...harcoal filter replaced in good time Is the air removed from the kitched replaced with a sufficient supply of fresh air so that no negative pressure develops Are the air outlets blocked During installation was the outlet air duct miscalculated or not properly installed e g diameter too small exhaust air pipe too long or exhaust air duct too angled The hood is suddenly much noisier during operation...

Page 11: ...ch rooms Nega tive pressure occurs in a closed room as soon as an extraction air system cooker hood is switched on Pressure may only be equalised with an inflow of fresh air from outside and not by means of the household furnace It must be ensured that no car bon monoxide is extracted from the heating source Suitable measures must be taken in order to ensure that there is a sufficient supply of fr...

Page 12: ...nsitions between pipe sections are fitted tightly and are waterproof This will prevent the used exhaust air from escaping unintentionally Electric connection The hood is fitted with a mains cable and a plug and can be con nected to any shockproof socket supplying 230 volts of alternat ing current 50 Hz which has been installed in accordance with regulations If the mains cable of this appliance is ...

Page 13: ...ddle above the cross section on the back Use the M5x20 screws supplied to adjust the body of the hood into a horizontal position Install the mounting bracket 1 for the top part of the chimney underneath the ceiling with screws and dowels Install the mounting bracket 2 for the bottom part of the chimney with screws and dowels Make the connection for extraction air see the previous section Switch th...

Page 14: ...delivery Install the two parts of the chimney that have been put together onto the body of the hood Here the longer bottom chimney part is hung up onto the mount ing bracket 2 Pressing it down a little will engage it properly into the groove of the hood body Pull the top part of the chimney upwards until it reaches the ceiling Fasten the top chimney part with screws 1 Recirculating air mode only 2...

Page 15: ... mm 650 1000 x 900 x 520 Extraction air connection piece Outer diameter mm 150 Weight approx kg 32 Electrical connection 2 lamps W Motor W 230 V 50Hz 4 5 75 195 Fan nominal output m3 h 755 Hood maximum extraction rate m3 h 257 629 Max noise db A 48 KD 12660 0GE KDUM 12660 0GE Dimensions Height Width Depth mm 650 1000 x 1200 x 520 Extraction air connection piece Outer diameter mm 150 Weight approx ...

Page 16: ... Teka Küchentechnik GmbH März 2010 ...

Reviews: