10.
Finding faults
Light does not work
-
Halogen lamp defect
Ö
Replace the lamp
-
Remove the halogen lamp
Ö
Check the connections
-
Relay does not activate
Ö
Replace the control unit
-
Relay activates
Ö
Replace the magnetic core transformer
Hood does not work
-
Mains connection OK
Ö
Check the connection
-
Fuse 3.15 A
Ö
Replace the fuse
-
Fuse OK
Ö
Replace the control unit
-
Motor connection OK
Ö
Replace the magnetic core transformer
Motor too loud
-
Out of balance
Ö
Replace the motor
-
Exhaust air path too narrow
Ö
Check the diameter and, if necessary, enlarge
-
Aluminium flexible pipe
Ö
4 db (A) louder
-
Motor only runs at one speed
Ö
Check the keys
-
Motor connection OK
Ö
Change the connections
-
Capacitor defect
Ö
Replace the control unit
-
Operating element defect
Ö
Replace the operating element
Operating element error
-
Operating element defect
Ö
Check the connection
-
Connection OK
Ö
Replace the operating element