22
H2-50-02
For internal use only
Activation of a setting procedure is shown in the display (17) when “MIN” is indicated. Now the cooking
zone burner that is to be set can be selected with the minus (12) or the plus (13) key of the programming
for the clock. The selected burner will light up in the display (16).
After confirmation with the clock key (11), the burner that is to be set is ignited at its lowest level and the
gas volume of the lowest level can be set with the + and - keys of the burner.
A - (minus) will appear in the power setting display (18) during the setting procedure when the minimum
setting is the same as the factory setting.
The display blinks and switches to A or v in order to display a higher or lower volume of gas in relation
to the pre-set volume. The clock key (11) must be pressed in order to confirm the required minimum
volume.
The “MIN” display remains visible and no LED blinks. Now the clock key (11) can be pressed to end the
process or the minus (12) and plus (13) keys of the clock programming in order to select a different
cooking zone burner and set the minimum gas volume. Minimum gas volumes are then picked up by the
appliance and saved for use in the normal operation of the hob.