background image

20

H2-50-02

For internal use only

Chart with the flow rates, the thermal output of the burners, the diameter of the injectors and the
operating pressure of the various types of gas

Table 3: 

Burners

Gas

Operating

pressure

Thermal output

Injector

diameter

Thermal output (W)

No.

Name

mbar

g/h

l/h

1/100 mm

min.

max.

1

Wok burner

G 30 - butane
G 31 - propane
G 20 - natural gas

50
50
20

244
239

319

73 F4
73 F4
128 Y

1900
1900
1500

3350
3350
3350

G 30 - butane (NL)
G 31 - propane (NL)
G 20 - natural gas (NL)
G 25 - natural gas (NL)

28-30

37
20
25

244
239

319
371

93
93

128 Y
135 K

1500
1500
1500
1500

3350
3350
3350
3350

2

Fast burner

G 30 - butane
G 31 - propane
G 20 - natural gas

50
50
20

204
200

267

70 M
70 M

117 Y

1050
1050

800

2800
2800
2800

G 30 - butane (NL)
G 31 - propane (NL)
G 20 - natural gas (NL)
G 25 - natural gas (NL)

28-30

37
20
25

204
200

267
310

83
83

117 Y

125 F 2

750
750
750
750

2800
2800
2800
2800

3

Semi-fast, 

front left

G 30 - butane
G 31 - propane
G 20 - natural gas

50
50
20

102
100

133

54 M
54 M

85 Y

1000
1000

750

1400
1400
1400

G 30 - butane (NL)
G 31 - propane (NL)
G 20 - natural gas (NL)
G 25 - natural gas (NL)

28-30

37
20
25

98
96

133
155

58
58

85 Y
89 K

550
550
550
550

1350
1350
1400
1400

4

Semi-fast, 

back left

G 30 - butane
G 31 - propane
G 20 - natural gas

50
50
20

127
125

167

59 M
59 M

98 Z

1000
1000

750

1750
1750
1750

G 30 - butane (NL)
G 31 - propane (NL)
G 20 - natural gas (NL)
G 25 - natural gas (NL)

28-30

37
20
25

127
125

167
194

65
65

98 Z
98 Y

550
550
550
550

1750
1750
1750
1750

5

Additional 

burner

G 30 - butane
G 31 - propane
G 20 - natural gas

50
50
20

73
71

95

42 M
42 M

75 X

750
750
550

1000
1000
1000

G 30 - butane (NL)
G 31 - propane (NL)
G 20 - natural gas (NL)
G 25 - natural gas (NL)

28-30

37
20
25

73
71

95

111

50
50

75 X

73 F 1

550
550
450
450

1000
1000
1000
1000

Summary of Contents for GKE 6840.0M

Page 1: ...Service Manual GKE 6840 0M GKE 9851 0M...

Page 2: ...l H2 50 02 Responsible Norbert Kirchmair K PPERSBUSCH HAUSGER TE AG Email norbert kirchmair kueppersbusch de Tel 0209 401 718 Customer Service Fax 0209 401 743 Postfach 100 132 Date 09 06 2011 45801 G...

Page 3: ...one burners 9 4 2 Other functions 10 4 2 1 Setting the switching off time of a cooking zone burner 10 4 2 2 Setting the clock 11 4 2 3 Key lock 12 4 2 4 Release of a cooking zone burner 13 4 2 5 Presc...

Page 4: ...sistance must not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functioning of the appliance On completion of repairs an inspection must be car...

Page 5: ...t Hob with an electronic cooking zone burner control system with touch controls 1 Wok burner 3350W 2 Fast burner 2800W 3 Front left semi fast cooking zone burner 1350 1400 W 4 Back left semi fast cook...

Page 6: ...ey 12 Back right cooking zone burner minus key 13 Back right cooking zone burner plus key 14 Front right cooking zone burner minus key 15 Front right cooking zone burner plus key 16 Wok burner minus k...

Page 7: ...lock with manual resetting through release of the key Setting of the switch off time for each burner Maximum operating time for each burner pre set in the memory duration of 4 hours Temperature readin...

Page 8: ...memory Possibility to administrate two modulation charts G20 and G30 Procedure integrated in the appliance for setting the smallest flame for each cooking zone burner Clock displaying the time of day...

Page 9: ...ck after the third attempt and the respective LED will show the letter b To unlock the cooking zone burner see Release of a cooking zone burner on page 13 Each cooking zone burner for which no timer h...

Page 10: ...urs will be continuously changed The clock key 11 must be pressed again to indicate the number of minutes Now the numbers on the right of the decimal point will flash Proceed the same as described for...

Page 11: ...n the left of the dot shows the hours and the minutes are shown on the right The hours can be raised or reduced by pressing the minus 12 or plus 13 keys When the minus 12 and plus 13 keys are kept pre...

Page 12: ...ndividual burners light up When the key lock is active neither the burner power settings nor the timer settings can be changed However the hob can be switched off at any time by pressing the on off ke...

Page 13: ...0 and can then be re ignited Please note If release is repeated 5 times in sequence in a period of 15 minutes the controls will show FLT06 and will not accept any request for release for another 15 m...

Page 14: ...the adjacent surfaces around the hob must be able to withstand an excessive temperature of 65K The adhesive connecting the plastic surface and the unit must be able to withstand temperatures of at lea...

Page 15: ...ling is flush with the outer edge of the glass panel The ends of the strips must fit together without overlapping Glue the sealing evenly and securely onto the glass pressing it on with your finger Po...

Page 16: ...ning gas safety The rear panel and the surfaces adjacent to and surrounding the hob must be able to withstand an excessive temperature of 65K 5 4 Electrical connection The electrical connection must b...

Page 17: ...ob After carrying out the activities defined above it will be possible to replace the electrically operated valves the electric components and the electronic card It is recommended that the gasket D i...

Page 18: ...for different types of gas by mounting main injectors in compliance with the type of gas used The burner heads will first of all need to be removed Then use a straight spanner B to screw out the injec...

Page 19: ...tched off Press keys 1 3 and 12 simultaneously for at least 2 seconds When the power setting displays 18 switch off the selection process for the gas type will have started At the same time the timer...

Page 20: ...gas NL G 25 natural gas NL 28 30 37 20 25 204 200 267 310 83 83 117 Y 125 F 2 750 750 750 750 2800 2800 2800 2800 3 Semi fast front left G 30 butane G 31 propane G 20 natural gas 50 50 20 102 100 133...

Page 21: ...The procedure for entering the minimum levels enables the pre determined minimum gas volume to be changed Each burner is adjusted to the existing type of gas to which the hob is connected The applianc...

Page 22: ...ll appear in the power setting display 18 during the setting procedure when the minimum setting is the same as the factory setting The display blinks and switches to A or v in order to display a highe...

Page 23: ...180 degrees If this does not delete the error message the electronic unit will have to be replaced Table 4 Type of fault Error code displayed Individual cooking zone burner blocked B Extra flames fau...

Page 24: ...ation electrode front right 3 Ionisation electrode back right 4 Ionisation electrode back left 5 Ionisation electrode front left 6 Ignition transformer 7 Master valve 8 Valve front right 9 Valve back...

Page 25: ...voltage average value for the respective type of gas Master valve Supply voltage 24V DC Natural gas Liquid gas 1 11 7 V 10 5 V DC 2 12 1 V 10 9 V DC 3 12 5 V 11 3 V DC 4 12 9 V 11 7 V DC 5 13 5 V 12...

Reviews: