36
GEH 6300.0
Technical data
Table of permitted gas types and gas pressures
Table of heat input
Total nominal heat input
= 11.7 kW
Connected load of the appliance
= 843 g/h
Electrical connection
Connection
standard mains plug into a wall socket.
Power consumption
at 230 V: 2.5 kW,
at 235 V: 2.6 kW
Power supply
230-240 V, 50 Hz
Fuse rating
16 A
Gross calorific values according to EN 437
The H
SB
calorific value can be obtained from the relevant gas supply company
upon installation.
The flow rate is calculated as follows:
heat input kW x 1000
Flow rate l/min =
--------------------------------------
gross calorific value kWh/m
3
x 60
Country
(ISO abbreviation)
Natural gas
H, E
(G 20)
Natural
gas LL
(G 25)
Natural gas
L
(G 25)
Pressure couple
natural gas E+
(G 20/25)
Propane
(G 31)
Pressure couple
(butane/propane)
(G 30/31)
Butane
(butane/propane)
(G 30)
Category
mbar
mbar
mbar
mbar
mbar
mbar
mbar
mbar
Germany (DE)
20
20
50
II
2ELL3B/P
Denmark (DK)
Finland (FI)
Sweden (SE)
Iceland (IS)
Norway (NO)
20
28-30
II
2H3B/P
Netherlands (NL)
25
25
50
28-30
II
2L3P
II
2L3B/P
France (FR)
Belgium (BE)
20/25
28-30/37
II
2E+3+
United Kingdom (GB)
Spain (ES)
Italy (IT)
Portugal (PT)
Ireland (IE)
Greece (GR)
20
28-30/37
II
2H3+
Austria (AT)
20
50
II
2H3B/P
Luxembourg (LU)
20
28-30/37
I
2E, I3+
Burners
Natural gas
20 mbar
25 mbar
Butane/propane gas
Input
kW
Input
kW
Gas rate
g/h
Simmering ring
high
1.1
1.1
79
low
0.3
0.3
22
Standard ring
high
1.9
1.9
137
low
0.38
0.38
27
High speed ring
high
2.8
2.8
202
low
0.56
0.56
40
Oven ring
high
4.0
4.0
288
low
1.0
1.0
72
Gas type
Calorific value H
s
15 °C
MJ/m
3
kWh/m
3
MJ/kg
kWh/kg
Natural gas H
(G 20)
37.78
10.5
Natural gas L (G 25)
32.49
9.03
Butane (G 30)
49.47
13.75
Propane (G 31)
50.37
14.00