
34
GEH 6300.0
Factory setting / conversion possibilities
This appliance can be converted to run on other types of gas.
[
Adjustment and conversion work should only be carried out by a qualified
gas fitter! The applicable rules and regulations should be observed.
Disconnect the appliance from the power supply so that it is completely
free of voltage.
[
The type of gas and the gas supply pressure must correspond to the gas
setting specified on the appliance. The factory setting is indicated on an
information plate or on the identification plate.
[
Any subsequent conversions to different types of gas must be
permanently marked on the nameplate of the appliance.
[
Only use special injectors obtained from the Customer Service.
Conversion injector sets
Injector table
Converting ring burners
Main injectors
If the ring burners are set to run on a different type or quality of gas the main
injector must be replaced.
– Remove the burner cover and plug-on accessories.
– Use a socket wrench to unscrew the injector.
– Place the new injector into the socket wrench and screw it in as far as it
will go.
Low flame injectors
After you have removed the control knobs (for the rings and the oven) and
removed the control panel (see below) the low flame injectors can be adjusted
or reset. If you are using natural gas and liquefied petroleum gas the low flame
injectors must be changed. Screw in the injectors as far as they will go (see
Injector Sets table).
– Disconnect the appliance from the
power supply (unplug from the mains
or switch off the fuse).
– Remove the control knobs (for rings
and oven).
– Open the oven door.
■
Important
: The control panel remains
connected to the appliance due to the electrical wiring. It must therefore be
handled with care!
– Unscrew the two screws on left and
right under the control panel and the
two behind it.
– Lift the control panel towards the front
and, holding it by the lower edge,
draw it slightly towards the front and
carefully remove it by lowering it
downwards.
– Unscrew the low flame
injectors
replace them and screw
the new ones in as far as
they will go.
Gas type, pressure
Injector sets
Natural gas H, E, E+, G 20 (20/25 mbar)
on demand
Natural gas L, LL, G 25 (20 mbar)
acc. No. 219
Natural gas L, G 25 (25 mbar)
on demand
Liquefied petroleum gas butane/propane,
G 30 (50 mbar)
acc. No. 211
Liquefied petroleum gas butane/propane,
G 30 (28-30/37 mbar)
acc. No. 218
Liquefied petroleum gas propane, G 31 (50 mbar)
on demand
Gas type, pressure
High speed ring
Standard ring
Simmering ring
Oven ring
Main
injector
Low setting
injector
Main
injector
Low setting
injector
Main
injector
Low setting
injector
Main
injector
Low setting
injector
Natural gas H, E, E+
G 20 (20/25 mbar)
125
56
93
47
72
41
150
77
Natural gas LL G 25 (20 mbar)
145
62
117
52
79
47
165
82
Natural gas L G 25 (25 mbar)
118
61
104
49
78
44
155
80
Liquefied petroleum gas butane/
propane G 30 (50 mbar)
73
34
62
26
49
23
82
44
Liquefied petroleum gas butane/
propane G 30 (28-30/37 mbar)
81
39
70
28
53
24
92
52
Liquefied petroleum gas propane
G 31 (50 mbar)
79
36
67
30
51
26
89
48