Resetting the oven burner
Main injector
When resetting the oven burner the burner injectors must be replaced.
– Loosen the cover plate.
– Then detach the air slide and the oven burner.
– Set the parts aside and unscrew the burner injector using a socket wrench
of type SW 14.
– Screw in the new injector as shown in the Injector table.
– Reinsert the burner and screw it down tightly.
– Adjust the air using the table below.
– Heat the oven at the highest temperature level for at least 10 minutes and
then turn it down to the lowest temperature level. The burner should burn
with a small, but steady flame.
Readjust the air if necessary.
The flames should burn steadily, but not as strongly as those of the ring
burners.
Guidelines for the air setting
Low setting injector
The readjustment is carried out at the oven thermostats (oven temperature
control). The control panel must first be removed. (See “Low flame injectors”).
For natural gas and liquefied petroleum gas
Unscrew the injector and replace it by the new injector. Screw in the new
injector as far as it will go.
Finally, check burning behaviour.
Final assembly
On completion of the conversion and setting work, final assembly can be
performed.
■
Once correctly installed the device is to be protected on all sides by covers
so that contacting any operationally insulated part is impossible.
■
The cover may only be removed by tools.
– Mount the control panel.
– Install the knobs for regulating the
cooking rings and the thermostat that
controls the oven.
Natural gas H, E, E+
3.0 mm
Natural gas L, LL
1.0 mm
Liquefied petroleum gas 50 mbar
2.5 mm
Liquefied petroleum gas 30/37 mbar
3.0 mm