EN
Bona Edge UX
Bona Edge UX
8
9
Instructions for electrical connection
Commencing Operation
Cables, extensions and plugs
Only use approved cables. The maximum
recommended cable length is 10 m; for greater
lengths use cables with a larger cross-section.
MACHINE WITH 230 V~50 Hz MOTOR 1.25 kW
For machines with a 230 V~50 Hz motor, a HO5VV-F-3x2,.5
mm2 HAR-approved power supply cable must be used along
with an approved SCHUKO 2P+E 16 A 200÷250 V plug.
The machine must never be moved using its cable and the
cable must never be pulled when disconnecting from the
socket.
Keep the cable away from sources of heat, oil and sharp
edges.
Using the machine with unsuitable and/or excessively long
cables may cause injury or damage to people or objects.
Safe and correct use
This instruction manual should be read carefully before
using the Bona Edge UX edge sander for the first time.
The instruction manual contains important information on
safety and preventing improper use of the machine and
will resolve any doubts or questions, making possible to
operate the machine safely and with ease. Removing safety
features could cause death or physical injury. Familiarize
yourself with the machine before using it for the first time.
The Bona Edge UX machine is suitable for the dry sanding of
floors. Any other use without the consent of the manufacturer is
prohibited. DO NOT use on wet floors.
See
‘Machine Warnings’
on page 11.
Keep hands and clothing away from moving mechanical parts.
If a situation arises wh
ich has not been desc
ribed in
this manual, contact y
our distributor or Bon
a
Representative.
Machine data plate
The following information can be found
on the machine data plate:
1) Name of the manufacturer
2) Machine model and P/N
3) Year of manufacture (see 7)
4) Motor power
5) Supply voltage and Frequency
6) Rated current
7) Seriennummer: z. B. NE1734727
• The first two numbers refer to the year of
manufacture (17= 2017)
• The second group of three numbers indicates the
day of the year the machine was manufactured
(347 = December 13
th
)
• The last two numbers indicate the progressive
number of machines produced that day of
manufacture (27= 27
th
machine produced that
day)
Introduction
This machine only operates
with the voltage and frequency
shown on the machine data
plate. Before connecting the
cable to the power supply
ensure the correct voltage and
frequency are available.
DO NOT expose the machine to rain. This machine is
intended for dry use only. Keep the machine in a dry
building and DO NOT use it in damp or wet places.
If the machine is not connected correctly to the electricity
network, death due to electrocution may occur. To
prevent electric shocks always use a grounded three
wire electrical system. For maximum protection against
electric shocks use a circuit protected with a differential
cut-out switch.
Tampering with the grounding plug in any way may result
in death from electrocution. DO NOT cut, remove or
break the grounding plug. If the socket does not match
the plug consult a qualified electrician.
If the machine is used with
a damaged plug or power
supply cable, death may
occur from electrocution.
If cables or plugs are worn
or damaged in any way,
have them replaced by the
manufacturer or certified
machine repair center in order