18
19
KTE3514
Weekly Program:
1 ~ 5 (Mon-Fri): P1
6 (Saturday): P2
7 (Sunday): P3
Factory presetting
Confort (
Economic (
AU: 1~5 (Monday ~ Friday): P1
6 (Saturday): P2
7 (Sunday): P3
Anti-frost ( empty
): 22°C
): 17°C
): 7°C
Note:
When pressing
to power on, the unit will come back on to
the factory pre-sets.
4 Other notes
• The screen has a back light. It will turn off after 1 minute if you don’t
press any buttons. It will light up again if you press any button.
• The unit has a button lock function. The buttons will be locked (
)
after 1 minute if you don’t press any buttons.
• To unlock: press
and
at same time.
• The time will be reset to
00:00
if you unplug the unit, or if there is
a power cut.
• This heater includes an overheat protection system that shuts off
the heater when parts are getting excessively hot.
• will only show when the unit is heating.
• The units will always go into free use mode from standby mode.
• The unit will return to the last operating mode when powered off
and on.
2.3. Maintenance
Always remove the plug from the socket and allow the heater to cool
down before cleaning it.
Wipe the exterior surface of the heater occasionally with a soft damp
cloth (not dripping wet) and dry the exterior surface before operating
the heater.
WARNING:
Do not immerse the heater in water.
Do not use any cleaning chemicals such as detergents and
abrasives. Do not allow the interior to get wet as this could
create a hazard.
Accumulated dust may be removed from the heater with a soft dry cloth.
To store the heater, put the heater back into its original packaging
and store it in a clean dry place.
In case of malfunction or if you have any doubt, do not try to repair
the heater by yourself, it may result in a fire hazard or electric shock.
3. TECHNICAL SPECIFICATIONS
MODEL NO
FINS
NET SIZE
RATED
VOLTAGE
RATED
POWER
KTE3514 /
NDFL791B-5R
5
575 x 590 x 80 mm
~230V/50HZ
900W
EN
electric radiator 900W