25
EN
EN
25
can3D
®
control panel
1
Status Camera
Purple: camera on
Not visible: camera off
2
Status locating transmitter
Purple: locating transmitter on
Black: locating transmitter off
3
Lighting
Purple: fl ash light
Black: permanent light
4
Mode
Up arrow: navigation mode
Eye: view mode
Down arrow: release mode
1
2
3
4
5
6
7
5
Brightness
Upper position: bright
Lower position: dark
6
Focus
Upper position: far
Lower position: close
7
Zoom
Upper position: max. zoom
Lower position: no zoom
INSPECTION
CamFlex
®
HD is pushed into a tube with the help of a rod. Thereby it is controlled via the
basic device or rather the software can3D
®
. The objective of the inspection is recording the
condition and run of the pipe.
Lighting
When the camera is connected to the basic device the LEDs are in permanent light mode. As
soon as the start of inspection is entered in the software, they automatically switch over to
fl ash light mode. A manual switch between the two modes is possible at any time. Make sure
that the permanent light mode is active as soon as the camera is outside a closed pipe.