Kuhse KEA 293 PST Operating Instruction Download Page 2

    Operating Instruction KEA 293 PST  - 

2 / 12

 -   File: 

BA_KEA 293 PST_EN_Ver 2016-07-01.doc

 

 

 

 

Alfred Kuhse GmbH

 

Telefon: +49 4171-798-0 

E-mail: [email protected] 

Subject to technical changes 

An der Kleinbahn 39,21423 Winsen 

Telefax; +49 4171-798-117 

http://www.kuhse.de 

 

 

2. 

 Content 

1.

 

General description............................................................................................................ 1

 

2.

 

Content ................................................................................................................................ 2

 

3.

 

Revision history ................................................................................................................. 3

 

4.

 

Warnings ............................................................................................................................. 3

 

5.

 

Displays and keys .............................................................................................................. 4

 

6.

 

Functions of the keys ........................................................................................................ 4

 

6.1.

 

Operating mode keys .......................................................................................................... 4

 

6.2.

 

Start key ............................................................................................................................... 4

 

6.3.

 

LED Test button ................................................................................................................... 4

 

6.4.

 

Alarm Off button ................................................................................................................... 4

 

7.

 

General displays ................................................................................................................ 5

 

7.1.

 

Monitoring on ....................................................................................................................... 5

 

7.2.

 

Automatic system locked ..................................................................................................... 5

 

7.3.

 

Start control .......................................................................................................................... 5

 

7.4.

 

Failed start / Motor malfunctions .......................................................................................... 5

 

8.

 

Operating modes ................................................................................................................ 5

 

8.1.

 

Off operating mode ............................................................................................................... 5

 

8.2.

 

Auto operating mode ............................................................................................................ 5

 

8.3.

 

Test operating mode ............................................................................................................ 6

 

8.4.

 

Sprinkler operation ............................................................................................................... 6

 

9.

 

Error messages / Programmable operation indicators .................................................. 6

 

9.1.

 

Use as an operational indicator ............................................................................................ 6

 

9.2.

 

Use as an error message ..................................................................................................... 6

 

9.3.

 

Alarms 9 and 10 ................................................................................................................... 6

 

9.4.

 

Internal error messages ....................................................................................................... 7

 

9.4.1.

 ..... 

Overspeed 

7

 

9.4.2.

 ..... 

Speed measurement failed 

7

 

9.4.3.

 ..... 

Engine does not switch off 

7

 

10.

 

Remote acknowledgement ................................................................................................ 7

 

11.

 

Speed regulation ................................................................................................................ 7

 

12.

 

Emergency Stop / Emergency Off (external) ................................................................... 7

 

13.

 

Start program ...................................................................................................................... 8

 

13.1.

 

Start process, diesel engine ................................................................................................. 8

 

13.2.

 

Start process, gas engine .................................................................................................... 8

 

14.

 

Technical data .................................................................................................................... 9

 

14.1.

 

Design .................................................................................................................................. 9

 

14.2.

 

Auxiliary voltage ................................................................................................................... 9

 

14.3.

 

Analogue input ..................................................................................................................... 9

 

14.4.

 

Digital inputs and outputs ..................................................................................................... 9

 

14.5.

 

Serial interface ..................................................................................................................... 9

 

14.6.

 

KNG for coupling to other systems (option) ......................................................................... 9

 

15.

 

Connection diagrams....................................................................................................... 10

 

15.1.

 

KEA 292 connection diagram ............................................................................................. 10

 

15.2.

 

Position of the voltage selector and connection terminals ................................................. 11

 

16.

 

Drilling template 

– Scale 1:1 – print without scaling!  .................................................. 12

 

 

 

Summary of Contents for KEA 293 PST

Page 1: ...All functions allocated to the genset are included for sprinkler operation Ten displays can be selected as alarms or operational indicators Provision has been made for remote acknowledgement of alarms...

Page 2: ...5 8 3 Test operating mode 6 8 4 Sprinkler operation 6 9 Error messages Programmable operation indicators 6 9 1 Use as an operational indicator 6 9 2 Use as an error message 6 9 3 Alarms 9 and 10 6 9 4...

Page 3: ...unit The connection regulations must be observed 3 The installation and commissioning must only be carried out by sufficiently qualified personnel 4 Applicable regulations especially those of the VDE...

Page 4: ...can be selected using the keys 6 2 Start key The motor can be started in MANUALoperating mode by actuating this button If the motor needs to be pre heated the pre heating device must be externally co...

Page 5: ...m is controlled by three criteria That s why this message has expired needs to be interpreted The message is controlled if the genset has not started at the end of the starting program This message FA...

Page 6: ...t is free Stopping can then be carried out via the OFF operating mode or always via Emergency Stop 9 Error messages Programmable operation indicators Any of the 10 LEDs can either display an error mes...

Page 7: ...et is immediately ready for operation in the event of a start request sprinkler request 10 Remote acknowledgement Existing alarms can be remotely acknowledged with a signal L on terminal 32 A constant...

Page 8: ...kler operation run on time 0 sec Stop time 30 sec 13 2 Start process gas engine Starter on If the starter speed is exceeded the switching on of the ignition is delayed e g after 2 sec Then another 2 s...

Page 9: ...70 C Operation 10 C 50 C Standards regulations DIN VDE 0160 14 2 Auxiliary voltage Switchable 9 12 15V or 14 24 35V DC 14 3 Analogue input Battery voltage monitor 14 4 Digital inputs and outputs Input...

Page 10: ...293 PST_EN_Ver 2016 07 01 doc 10 Alfred Kuhse GmbH Telephone 49 4171 798 0 E mail kuhse kuhse de Subject to technical changes An der Kleinbahn 39 21423 Winsen Fax 49 0 4171 798 117 http www kuhse de 1...

Page 11: ...ST_EN_Ver 2016 07 01 doc 11 Alfred Kuhse GmbH Telephone 49 0 4171 798 0 E mail kuhse kuhse de Subject to technical changes An der Kleinbahn 39 21423 Winsen Fax 49 0 4171 798 117 http www kuhse de 15 2...

Page 12: ...Operating instructions KEA 293 PST 12 12 File BA_KEA 293 PST_EN_Ver 2016 07 01 doc 16 Drilling template Scale 1 1 print without scaling...

Reviews: