14.
Technical data
14.1.
Design
Unit for front installation
Dimension (
,
, depth) 260 x 170 x 80 mm
Weight approx. 2.2 kg
Installation position arbitrary
Protection class (installed) IP 44
Ambient temperature:
- Storage -20°C - +70 °C
- Operation -10 °C - +50 °C
Standards/regulations DIN VDE 0160
14.2.
Auxiliary voltage
Switchable 9-12-15V or 14-24-35V DC
14.3.
Analogue input
Battery voltage monitor
14.4.
Digital inputs and outputs
Input for generator D+ with pre-excitation for AC generators
10 connections for alarm contacts
13 general control inputs
10 output relays, of which 7 are parameterisable, Contact load max. 35V DC, 1 A
Input for pick-up for the speed measurement
14.5.
Serial interface
USB interface for parameterisation.
14.6.
KNG for coupling to other systems (option)
Device for clipping onto top-hat rails: KNG (Kuhse Network Gateway) for coupling to other systems via
PROFIBUS DP or Modbus RTU