4 - 10
Command sequences
Mixed character attribute assignment
Hex
1Bh
47h
ATTR
AP
Decimal 27
73
ATTR
AP
ASCII
ESC
G
ATTR
AP
With this command, mixed character attributes can be as-
signed. All characters after this command are noted with this
attribute until a new attribute command alters the current char-
acter attribute. The command does not affect characters which
are on the screen already.
The parameter ATTR
AP
can take on the following values:
ATTR
AP
Function
0
Reset of all attributes
1
Assign character attributes as in the last "ESC G"
sequence
2
Deactivate flashing
3
Activate flashing
4
Activate inverse
5
Deactivate inverse
6
Activate inverse and flashing
7
Deactivate inverse and flashing
the following are possible only with KDT 635:
8
Activate underlining
9
Deactivate underlining
:
Activate flashing and underlining
;
Deactivate flashing and underlining
<
Activate inverse and underlining
=
Deactivate inverse and underlining
>
Activate inverse, flashing and underlining
?
Deactivate inverse, flashing and underlining