4 - 14

Command sequences

Activate status line

Hex

1Bh

67h

Decimal 27

104

ASCII

ESC

g
This displays the contents of the status line. The command has
no effect if there is no line defined as status line. The same sta-
tus line is displayed on all screen pages.

Deactivate status line

Hex

1Bh

68h

Decimal 27

104

ASCII

ESC

h
The status line is deactivated. The contents of the status line is
not deleted by this command.

Clear status line

Hex

1Bh

1Bh

59h

Decimal 27

27

89

ASCII

ESC

ESC

Y

The status line is overwritten by spaces of the current character
attribute.

Summary of Contents for KDT 633

Page 1: ...nance and servicing 2 4 2 5 Electromagnetic compatibility 2 5 2 5 1 Definition 2 5 2 5 2 Resistance to interference 2 5 2 5 3 Interference emission 2 6 2 5 4 General notes on installation 2 6 2 5 5 Pr...

Page 2: ...2 Function Display Anzeige 3 14 3 2 6 3 Function Keyboard Tastatur 3 14 3 2 6 4 Function LED File LED Datei 3 14 3 2 6 5 Function Serial 1 Seriell 1 3 15 3 2 6 5 Function Miscellaneous Sonstiges 3 15...

Page 3: ...4 19 4 3 2 Switching of LED s light emitting diodes 4 19 4 3 3 Character set changeover 4 20 Appendix A Technicalspecifications A 1 A 1 KDT 635 A 1 A 2 KDT 633 A 2 B Charactersets B 1 B 1 ASCII table...

Page 4: ...Contents 4 Table of contents...

Page 5: ...V 24 interface Advantages of operator prompting Dialog oriented communication between man and machine Digital input and output of the processing parameters Plaintext error diagnosis Graphic visualizat...

Page 6: ...al is directly conneted to the programming interface No further arrangements have to be made in the user program Slave mode Only possible in combination with the controls KUAX 657 657P and 653W Commun...

Page 7: ...ability Reliability of Kuhnke controllers is brought to the highest pos sible standards by extensive and cost effective means in their designandmanufacture Theseinclude selectinghigh qualitycomponents...

Page 8: ...geifthedescribed precautionsarenottaken 2 3 2 Dangers caused by high contact voltage This symbol warns you of dangers of death or grievous bodily harm which may be caused by high contact voltage if th...

Page 9: ...izedinaccordancewithEN 60204 IEC 204 VDE 0113 Theymustbeeffectiveatanytime Safetyandprecautionsregulationsforqualifiedapplications havetobeobserved Pleasepayparticularattentiontothenotesofwarningwhich...

Page 10: ...y be made by specially trained Kuhnke staff usually in the main factory in Malente Warranty expires in everyothercase Spareparts OnlyusepartsapprovedofbyKuhnke OnlygenuineKuhnke modulesmustbeusedinmod...

Page 11: ...noise dependsontheexactlocation Itisdeterminedintherelevant productstandards Theinternationalstandardregulatingconstructionanddegree ofnoiseresistanceofprogrammablelogiccontrollersisIEC 1131 2 which i...

Page 12: ...ues are fitting the controller into an earthed metal cabinet and equipping the supply cables with filters 2 5 4 General notes on installation As component parts of machines facilities and systems ele...

Page 13: ...Ensurepracticalwiring and laying of cables 2 5 6 Cable routing and wiring Separate laying of power supply circuits never together with controlcurrentloops DCvoltage 60 V 400 V ACvoltage 25 V 400 V Jo...

Page 14: ...hinesandvehicles Electromagnetic interference Considerelectromagneticinterferencefromvarioussources near the location of installation motors switching devices switchingthyristors radio controlleddevic...

Page 15: ...3 1 KDT 635 3 Hardware 3 1 635 For an overview of the technical specifications see appendix A Technical specifications 3 1 1...

Page 16: ...3 2 Hardware 3 1 2...

Page 17: ...3 3 KDT 635 3 1 2 Display Cursor keys Numeric keypad Enter key Firm logo Function keys F1 F8 Decimal point Plus Minus key Function keys F9 F16 with LED s...

Page 18: ...5 F6 F7 F8 F9 Code 11 12 13 14 18 19 1A 1B 01 Release code 91 92 93 94 98 99 9A 9B 81 Key F10 F11 F12 F13 F14 F15 F16 Code 02 03 04 08 09 0A 0B Release code 82 83 84 88 89 8A 8B Key Enter 0 Code 2D 2C...

Page 19: ...set the brightness Release key F1 To decrease the brightness Press and hold key F1 Press key as often as necessary to set the brightness Release key F1 3 1 7 For this hook switch S1 at the rear panel...

Page 20: ...Gnd DSR RTS CTS RI 657 151 03 D Sub 9 p 3 1 8 3 1 8 1 635 For programming Order number 657 151 03 3 1 8 2 635 232 For communication via KUBES protocol Order number 635 151 01 KDT 635 KDT 633 Control 1...

Page 21: ...635 3 1 8 3 635 24 For communication via V 24 slave Order number 635 151 02 KDT 635 KDT 633 PC 1 2 3 4 5 6 7 8 9 D Sub 9 p 1 2 3 4 5 6 7 8 9 TxD RxD Gnd CTS RTS RxD TxD Gnd DSR RTS CTS RI 657 151 03 D...

Page 22: ...3 8 Hardware...

Page 23: ...3 9 KDT 633 3 2 KDT 633 For an overview of the technical specifications see appendix A Technical specifications 3 2 1 Diagram...

Page 24: ...3 10 Hardware 3 2 2 Dimensions mountingdimensions Top view Front view Side view Rear view Power supply 24 V DC V 24 connector Memory slots Monitor Data memory...

Page 25: ...3 11 KDT 633 3 2 3 Front view Cursor keys Display Numeric keypad Enter key Firm logo Decimal point Plus Minus key Function keys F1 F12...

Page 26: ...ey F1 F2 F3 F4 F5 F6 F7 F8 F9 Code 11 12 13 14 18 19 1A 1B 01 Release code 91 92 93 94 98 99 9A 9B 81 Key F10 F11 F12 Code 02 03 04 Release code 82 83 84 Key Enter 0 Code 2D 2C 2E 2F 29 2B 23 30 Key 1...

Page 27: ...s follows Setup KDT633 Uhr Ze 09 14 41 Da 04 09 95 Anzeige He 020 Cg 8 In Bl Tastatur Sw 350 Ww 250 Wi LED Datei BW 400 Ko Seriell 1 Ba 9600 Da 8 Pa 0 St 1 Sonstiges Grundeinstellung Ende Settings sel...

Page 28: ...ed outside the setup function in normal mode F1 or F1 3 2 6 3 Function Keyboard Tastatur Adjusts the keyboard delay this is the time a key has to be pressed until it is recognized and the repeat funct...

Page 29: ...5 FunctionMiscellaneous Sonstiges This topic hides several functions Choose function or Start function Enter Functions Grundeinstellung base setting for all previously described functions letzter Fehl...

Page 30: ...S protocol For communication via KUBES protocol Bestellnummer 635 151 01 KDT 635 KDT 633 PC 1 2 3 4 5 6 7 8 9 D Sub 9 p 1 2 3 4 5 6 7 8 9 TxD RxD Gnd CTS RTS RxD TxD Gnd DSR RTS CTS RI 657 151 03 D Su...

Page 31: ...3 KDT 633 V 24 Slave For communication via V 24 slave Dieses Kabel wird von Kuhnke nicht geliefert KDT 633 V 24 Slave 1 2 3 4 5 6 7 8 9 D Sub 9 p 1 2 3 7 4 5 8 TxD RxD DTR Gnd CTS RTS TxD RxD Gnd RTS...

Page 32: ...3 18 Hardware...

Page 33: ...ed that does not belong to the command the command recognition is aborted and the sign is displayed on the screen KDT 635 and KDT 633 are programmed by using command sequences which follow the common...

Page 34: ...the code of which is interpreted as a numeric value AP ASCII parameter An ASCII character is expected as parameter NP Numeric parameter The parameter consists of a se quence of numbers ASCII codes 0 9...

Page 35: ...ft hand character position already Cursor left Hex 06h Decimal 6 ASCII ACK This command moves the cursor by one character position to the left The cursor does not move if it is at the most left hand c...

Page 36: ...1 ASCII VT The cursor moves one line up unless it is in the topmost line of the writing area already In this case it stays at its current posi tion This is also applicable if the cursor is in the topm...

Page 37: ...line Cursor to the left margin Carriage return Hex 0Dh Decimal 13 ASCII CR The cursor moves to the leftmost character position of the cur rent line Cursor home Cursor in start position Hex 1Eh Decimal...

Page 38: ...an be posi tioned outside the set scroll area Example 1Bh 1Dh 20 20 This command brings the cursor to position 0 0 of the writing area Readout of the cursor position Hex 1Bh 3Fh Decimal 27 63 ASCII ES...

Page 39: ...635 Hex 1Bh 1Bh 2Ah Decimal 27 27 42 ASCII ESC ESC The scroll area is cleared and the cursor is positioned in the up per left corner of the scroll area Line delete from cursor position Hex 1Bh 54h or...

Page 40: ...of the contents of the lower line of the scroll area or if the cursor is outside the scroll area of the writing area The cursor position is not affected by this com mand Line delete Hex 1Bh 52h Decim...

Page 41: ...nd are noted with this attribute until a new attribute command alters the current char acter attribute The command does not affect characters which are on the screen already The parameter ATTRAP can t...

Page 42: ...AP can take on the following values ATTRAP Function 0 Reset of all attributes 1 Assign character attributes as in the last ESC G sequence 2 Deactivate flashing 3 Activate flashing 4 Activate inverse 5...

Page 43: ...ration the screen memory of the KDT 635 can store up to 4 screens simultaneouly between which can be switched instantaneously without a new screen creation by the host computer Each screen has its own...

Page 44: ...indicates whether a screen line and if so which is used as status line The following parameter values are accepted MODEAP Function 0 There is no status line being used Up to 25 lines are available as...

Page 45: ...EXT is noted with the character attributes as they were as signed before transferring this command TEXT may contain special control characters which are explained in the following example Backspace He...

Page 46: ...efined as status line The same sta tus line is displayed on all screen pages Deactivate status line Hex 1Bh 68h Decimal 27 104 ASCII ESC h The status line is deactivated The contents of the status lin...

Page 47: ...e left with absolute but never with relative cursor pos ition In one special case i e the origin mode the scroll area cannot be left by any positioning command In this case the upper left screen corne...

Page 48: ...origin mode If the cursor is outside the scroll area it is reset to home position upper left corner of the scroll area Deactivate origin mode Hex 1Bh 5Bh 3Fh 36h 6Ch Decimal 27 91 53 54 108 ASCII ESC...

Page 49: ...D DNP MNP YNP This command sets the date in the realtime clock Day DNP month MNP and year YNP are transferred to the terminal Example 1Bh 1Bh 53h 44h 31h 34h 3Ah 31h 32h 3Ah 39h 30h 3Bh The date is s...

Page 50: ...ime clock Hours HNP minutes MNP and seconds SNP are transferred to the terminal Example 1Bh 1Bh 53h 54h 31h 33h 3Ah 30h 30h 3Ah 33h 30h 3Bh The time is set to 12 00 30 Read time Hex 1Bh 1Bh 47 54h Dec...

Page 51: ...4 3 2 Switching of LED s light emitting diodes Switching of LEDs possible only with KDT 635 Hex 1Bh 53h 4Ch LEDNR 3Bh STATUS 3Bh Decimal 27 83 76 LEDNR 59 STATUS 59 ASCII ESC S L LEDNR STATUS The LED...

Page 52: ...4 20 Commandsequences 4 3 3 Character set changeover Character set changeover Hex 1Bh 20h 50Ch NR 3Bh Decimal 27 83 80 NR 59 ASCII ESC blank P NR NR goes from 30 38...

Page 53: ...onitor Data EPROM Data Memory Card EPROM 27C512 KDT 635 Standard EPROM 27C1001 128 KByte 27C2001 256 KByte or 27C4001 512 KByte 128 KByte order no 635 180 01 256 KByte or 512 KByte 1 1 2 Real time clo...

Page 54: ...x 80 Memory media Monitor Data EPROM 1 Data RAM 1 EPROM 27C512 KDT 633 Standard EPROM 27C1001 128 KByte RAM DS1245Y or DS1245AB 128 KByte with built in battery 10 years type DALLAS 2 3 Real time clock...

Page 55: ...E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o DEL Example the symbol NAK is assig...

Page 56: ...B 2 Appendix B B 2 Character set KDT 635 KDT 633...

Page 57: ...danger 2 2 Date 4 17 Dauertest KDT 633 3 15 DecimalCoding 4 1 Dimensions KDT 633 3 10 KDT 635 3 2 Displaycontrol 4 3 E electromagnetic compatibility 2 5 electrostatic discharge 2 5 emergencystop 2 3 E...

Page 58: ...anceto interference 2 5 S safety 2 1 Scrollarea 4 15 Serial 1 KDT 633 3 15 Seriell 1 KDT 633 3 15 servicing tobeobserved 2 4 Setupmenu KDT 633 3 13 Slavemode 1 2 Softwarereset KDT 633 3 12 KDT 635 3 5...

Reviews: