4.15.3.1 Inputs
In the Inputs group, see the following input values:
Variable
Data type Meaning
StateWord
UINT
Status word
Bit0
RS485 Receive data available
Bit1
RS485 Receive data overflow
Bit2
Short circuit (overload) outputs
Bit3
Undervoltage CPU
Bit4
Undervoltage In/Out (Load)
Bit5
EtherCAT Watchdog error
Bit6..15 unused
DigitalInput0
BOOL
Digital Input0
DigitalInput1
BOOL
Digital Input1
DigitalInput2
BOOL
Digital Input2
DigitalInput3
BOOL
Digital Input3
DigitalInput4
BOOL
Digital Input4
DigitalInput5
BOOL
Digital Input5
DigitalInput6
BOOL
Digital Input6
DigitalInput7
BOOL
Digital Input7
Counter
UDINT
Value of the event counter associated to DI5..7
SampleCycleCounter UINT
is incremented, when new analog values are present
4.15.3.2 AnalogIn0
In the AnalogIn1 group, see the following input values:
Variable
Data type Meaning
AnalogIn0_Sample0
UINT
Analog Input 0, Sample n
AnalogIn0_Sample1
UINT
Analog Input 0, Sample n+1
AnalogIn0_Sample2
UINT
Analog Input 0, Sample n+2
AnalogIn0_Sample3
UINT
Analog Input 0, Sample n+3
AnalogIn0_Sample4
UINT
Analog Input 0, Sample n+4
4.15.3.3 AnalogIn1
In the AnalogIn1 group, see the following input values:
Variable
Data type Meaning
AnalogIn1_Sample0
UINT
Analog Input 1, Sample n
AnalogIn1_Sample1
UINT
Analog Input 1, Sample n+1
AnalogIn1_Sample2
UINT
Analog Input 1, Sample n+2
AnalogIn1_Sample3
UINT
Analog Input 1, Sample n+3
AnalogIn1_Sample4
UINT
Analog Input 1, Sample n+4