7 Appendix
7.1 Technical data (Overview)
7.1.1 System properties Kuhnke FIO
Fieldbus ......................................................... EtherCAT 100Mbit/s
Dimensions .................................................... 25mm x 120mm x 90mm (W x H x D)
Housing mount .............................................. aluminum
Shield ............................................................. connected straight to module housing
Installation ...................................................... 35mm DIN rail (top-hat rail)
IO connection................................................. spring-assisted combi plug with mechanical ejector,
4 … 36-pin
Signal indication ............................................ LED located next to the terminal
Diagnosis ....................................................... LED: bus state, module state, broken wire/excessive
current
Number of ports ............................................. up to 32 digital I/Os on every module, up to 8 analogue
channels per module
Supply voltage ............................................... 24 VDC -20%/+25%
Number of I/O modules ................................. 20 per bus coupler (total max. power consumption:3A)
Electrical insulation ........................................ modules electrically insulated from one another and from
the bus
Storage temperature ...................................... -25°C …+ 70°C
Operating temperature .................................. 0°C ... + 55°C
Rel. humidity .................................................. 5% … 95%, non-condensing
Protection ....................................................... IP20
Susceptibility to noise .................................... zone B to EN 61131-2, Installation on an earthed top hat
rail in the earthed control
7.1.2 Kuhnke FIO bus coupler
Part no ........................................................... 694.400.00
Fieldbus ......................................................... EtherCAT 100Mbit/s 100 base TX to IEEE802.3
Connector ...................................................... 2x RJ45
Controller ....................................................... ASIC ET1100
Extensions ..................................................... connection to first Kuhnke FIO I/O module integrated in
side panel of module
Diagnosis ....................................................... LED:
EtherCAT module state
EtherCAT In/Out state
7.1.3 Kuhnke FIO bus coupler DI16/DO16
Part no ........................................................... 694.400.10
Fieldbus ......................................................... EtherCAT 100Mbit/s 100 base TX to IEEE802.3
Connector ...................................................... 2x RJ45
Controller ....................................................... ASIC ET1100
Extensions ..................................................... connection to first Kuhnke FIO I/O module integrated in
side panel of module