8. - Instructions for work
GA6501
41
KN255AGB F
Gyrorake
8.2
Adjustments in working position
8.2.1 Working width
From the working position:
- Raise machine using tractor lift linkage so that
wheels are no longer in contact with the ground.
- Shut-off valve (1).
- Using the provided key, loosen counter-nuts and
screws (1).
Before making any adjustment:
- Check that nobody is within the machine
pivoting area.
- If there is someone, make sure the person
moves away.
It is possible to angle the rotor arms slightly
downwards for easier rotor extension or
upwards for easier rotor retraction.
1
1
1