11. - Maintenance and storage
FC2860-3160-3560 TLR/TLS
85
KN282CGB_A
Mower conditioner
When draining and refilling, it is recommended to
use either a mineral base oil with viscosity grade
SAE 80W90 and API grade GL5, or a synthetic
base oil, type PAO (Poly-Alpha-Olefins) with a
viscosity grade equivalent to SAE 75W90.
- Unscrew dipstick plug (1) and its seal.
- Place a container of sufficient capacity under drain
plug.
- Remove drain plug (2) and its washer.
- Allow oil to drain completely.
- Wait for dripping to stop.
-
Clean and reinstall drain plug (2) and its
washer. (Replace if necessary).
- Pour the recommended oil quantity and quality
through the opening of fill/dipstick plug (1).
- Check oil level in upper gearbox:
• The "MAX" level corresponds to the mark on the
dipstick plug.
• The "MIN" level corresponds to the end of the
dipstick plug.
-
Clean and reinstall dipstick plug (1) and its
seal. (Replace if necessary).
11.4 Maintenance
11.4.1 Checking the oil levels
Gyrodine gearbox
- Check Gyrodine gearbox level:
• The "MAX" level corresponds to the mark on the
dipstick plug (A).
• The "MIN" level corresponds to the end of the
dipstick plug (B).
2
1
B
A