![KUHN CONTROLOR Instruction Manual Download Page 15](http://html1.mh-extra.com/html/kuhn/controlor/controlor_instruction-manual_2009402015.webp)
15
3.3. Keys for modifying the number of rows while working
These keys are used to increase or decrease the number of rows monitored.
- press key
ou
to disable the control of rows from the left-hand side or the right-hand side.
Note: this only disables the control of the rows and does not shut off the element.
- The display is divided into two parts: the rows that are not controlled on the right-hand side are displayed on the
right and the rows not controlled on the left-hand side are displayed on the left.
- Press key
to disable row control. When you press the key once, you disable control over one row, when
you press it twice you disable control over two rows and so on.
- To enable row control, proceed in the same way. Press key
to enable the rows one after the other or
key
to enable all the rows at the same time.