slicing software.
Slots in the bottom cover provide an air inlet for
the cooling unit.
When the 3D Printer is switched off the internal
real-time clock of the Mini PC is fed by two
external batteries so that the system's time
signal is not lost.
The solid state relays switch the four heating
resistors of the
build chamber
heating and the
heating resistor of the
print table
.
No. Description
6
Cooling unit radiator
7
Cooling unit pump
The cooling unit consists of a pump with water
reservoir, a radiator and the closed loop coolant
circuit filled with an electronic cooling liquid. It is
automatically switched on and off when the build
chamber is activated/deactivated.
The coolant is pumped in a circle past the
motors
and the
extruder nozzles
where it
absorbs heat which is then emitted via the
radiator.
Check the coolant level
monthly
and if required,
refill as described in the
Service Guide
.
Inside view of the electronic chamber (right
side).
No. Description
8 Type plate
9 Cooling unit radiator grill
10 Mains plug
11 Main switch
12 RJ45 ethernet plug
13 230V supply cable with Schuko plug
At the rear cover you find the mains plug and
the main switch of the mains adapter and the
RJ45 ethernet plug for the network connection.
The cooling systems' accumulated warmth is
dissipated via the radiator grill to the outside.
The
type plate
is positioned next to the fixing
screws of the cooling water pump.