background image

Pin Power Color Moving Head

User Manual

Summary of Contents for LM 2013

Page 1: ...Pin Power Color Moving Head User Manual ...

Page 2: ...e warning messages Ignoring these messages could result in serious personal injury This symbol indicates the minimum distance from a lighted object Warranty information Limited Warranty Unless otherwise stated your product is covered by a one year parts warranty to be counted from shipment date The buyer must provide receipts or invoices for verification of purchase and date If purchase date canno...

Page 3: ...nd Configuration 10 Unpacking the fixture 10 Installing a power cable cab 10 Mounting the fixture 10 Mounting the fixture upright 11 Safety Cable 11 Clamp 11 Mounting Procedure 11 Linking Fixtures 12 Cable Connectors 12 Connecting to the Link 12 Powering On the Fixture 13 Setting the DMX Start Channel 13 Shutting Down the Fixture 13 Chapter 3 The Menu System 14 Menu navigation 14 Menu map 14 Menu ...

Page 4: ...vs 16 bit DMX Parameters 21 Determining a DMX Start Channel 21 Protocol modes 22 DMX Protocols 22 HSV mode 7 channels 22 Stage mode 12 channels 22 Stage mode 9 channels 24 Stage mode 8 channels 24 Stage mode 5 channels 24 Chapter 5 Fixture control 25 Pan and Tilt 25 Dimming 25 Color wheel 25 Appendix 26 Important Safety Information 26 Warning For Continued Protection Against Fire 26 Warning For Co...

Page 5: ...cts Due to its small size and light weight it can be installed almost anywhere has a very low power consumption suitable for both rental and installation applications Easy set up and installation Features Operation 540º 630º pan and 240º tilt movement RGB color mixing Smooth dimmer from 0 to 100 Auto switching power supply 100 240 V AC power input CTC function color wheel strobe Construction Neutr...

Page 6: ... mm Fixture Weight 3 6 kg Shipping dimensions weight Single fixture carton Dimensions 280 mm x 175 mm x 340 mm Weight 4 1 kg Four fixtures carton Dimensions 595 mm x 365 mm x 360 mm Weight 18 kg Flight case dimensions 8 pcs case Dimensions mm x mm x mm Weight Kg Case 8 Fixtures 8 ...

Page 7: ...on a suitable and stable surface Electrical Optical information Power Input 100 240 VAC 50 60 Hz 120 W Light Source 36 pcs 3 watt RGB CREE XP E LEDs Beam Angle 8º Color Mixing RGB Operation Pan 540º or 630º selectable Tilt 240º Control DMX 512 Minimum distance to lighted object 1 meter DMX connectors 5 pin male and female XLR connectors Maximum ambient operating temperature 40º C Minimum ambient o...

Page 8: ... product in its shipping box or flight case Installing a power cable cab The LM 2013 fixture is shipped without a power cable although it is ordered by customer When installing the power cord be sure you chose Neutrik PowerCon input connector as main power input and chose the correct cord cap for your area Please note that our standard cores in the mains lead are colored according to the following...

Page 9: ...esigns dealer distributor see Related Products and Accessories on page 5 Clamp You must supply your own clamps and verify the clamp is capable of supporting the weight of the fixture You can order C clamps for truss mounting from your Conic Lighting Designs dealer distributor see Related Products and Accessories on page 5 Mounting Procedure To mount fixtures on a truss 1 Disconnect power to the fi...

Page 10: ...w a secondary data link to pass through the fixture Test each cable with a voltage ohm meter VOM to verify correct polarity and to make sure that the negative and positive pins are not grounded or shorted to the shield or to each other Connecting to the Link To link one or more fixtures to a DMX controller 1 Connect the male XLR connector of a DMX Data cable to the controller s DMX Data Out connec...

Page 11: ...3 The display will show the start channel currently assigned to the fixture 4 Use the Up and Down arrow buttons to select a new DMX start channel The display will show a new option ready for selection 5 Press the Enter button to store the new DMX Start channel The display will stop flashing when a new option is entered When setting the Start channel on a fixture remember A fixture s physical locat...

Page 12: ...ainst over heat SET TC Switch OFF Disables self protection against over heat SET TC Switch TC Switch Temp Cap Shows the current setting for temp value SET TC Switch Set Sets the temperature value for self protection SET Scan Setting Reverse Pan ON Sets reverse Pan ON SET Scan Setting OFF Sets reverse Pan OFF SET Scan Setting Reverse Tilt ON Sets reverse Tilt ON SET Scan Setting OFF Sets reverse Ti...

Page 13: ...s lost DMX Menu DMX Channels HSV Mode Selects HSV protocol DMX Menu DMX Channels STAGE Mode 12 Channels Selects 12 channels protocol DMX Menu DMX Channels STAGE Mode 9 Channels Selects 9 channels protocol DMX Menu DMX Channels STAGE Mode 8 Channels Selects 8 channels protocol DMX Menu DMX Channels STAGE Mode 5 Channels Selects 5 channels protocol Macro Menu Step quantity 62 Sets number of steps of...

Page 14: ... DMX signal Stop Run DMX Channels Stage 12 channels The Load Parameter menu option displays On if all the factory options are at the factory default settings If any of the items listed above are not at the factory default setting the display reads OFF Selecting the OFF option will have no effect To restore the factory default setting 1 Press Set Esc until SET appears on the display Press Enter 2 S...

Page 15: ...rotection To set Tc Switch Mask on 1 Press Set Esc until SET appears on the display Press Enter 2 Scroll to the TC Switch menu Press Enter 3 Scroll to TC Switch Mask Press Enter 4 Scroll to ON 5 Press Enter to store TC Switch Temp It sets the temperature value for the fixture to self protect To see the current settings for temperature value 1 Press Set Esc until SET appears on the display Press En...

Page 16: ...behavior will be normal 1 Press Set Esc until SET appears on the display Press Enter 2 Scroll to the Scan Setting menu Press Enter Scroll to the Reverse Pan menu Press Enter 3 Scroll to the Scan blackout Press Enter 4 Scroll to ON Press Enter to store Feed Back Feed Back menu option enables disables pan tilt position feedback correction system To enable it 1 Press Set Esc until SET appears on the ...

Page 17: ...l identifies each fixture on a DMX link You must assign a DMX start channel to each fixture on the link The DMX Address menu allows you to change the DMX start channel that is currently assigned to the fixture Be sure you do not overlap fixture channel ranges when changing the DMX start channel To change the DMX start channel 1 Press Up until DMX Menu appears on the display Press Enter to select 2...

Page 18: ... the display Press Enter to select 3 Scroll the menu until Stage Mode appears on the display Press Enter to select 4 Scroll the menu until the desired number of channels mode appears on the display Press Enter to store The MACRO Menu You can set up macros manually though this menu option To access the Macro Menu press Up Step quantity Sets the number of steps for the macro Maximum steps is 62 Prog...

Page 19: ...e increments The first channel of the pair provides coarse control changes of the DMX value in increments of 256 The second channel provides fine control and changes of the DMX value in increments of 1 Individual access of the two DMX channels used with 16 bit parameters varies by lighting console Most modern DMX consoles bind these two channels into a single 16 bit parameter to accurately perform...

Page 20: ...ue 2 Saturation 000 255 0 to 100 Saturation 3 Value 000 255 0 to 100 Value 4 Pan 000 255 Pan 0 to 540º 630º1 5 Pan 000 255 Pan fine 6 Tilt 000 255 Tilt 0 to 240º 7 Tilt 000 255 Tilt fine Stage mode 12 channels Ch Function DMX Value Description 1 Strobe 000 019 020 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 255 Shutter ope...

Page 21: ...69 070 074 075 079 080 084 085 089 090 094 095 099 100 104 105 109 110 114 115 119 120 124 125 129 130 134 135 139 140 144 145 149 150 154 155 159 160 164 165 169 170 174 175 179 180 255 RGB Dimmer channels are enabled Moroccan pink Pink Special rose pink Follies pink Fuchsia pink Surprise pink Congo Blue Tokyo Blue Deep Blue Just Blue Medium Blue Double CT Blue Slate Blue Full CT Blue Half CT Blu...

Page 22: ...o slow Shutter open Strobe8 random burst pulse fast to slow Shutter open 6 Pan 000 255 Pan 0 to 540º 630º1 7 Pan 000 255 Pan fine 8 Tilt 000 255 Tilt 0 to 240º 9 Tilt 000 255 Tilt fine Stage mode 8 channels Ch Function DMX Value Description 1 Red 000 255 Red 0 to 100 intensity 2 Green 000 255 Green 0 to 100 intensity 3 Blue 000 255 Blue 0 to 100 intensity 4 Dimmer 000 255 0 to 100 intensity 5 Pan ...

Page 23: ...ng User can choose between three dimming options Square Law dimming is finer at low levels and coarser at high levels Inverse Square Law dimming is coarser at low levels and finer at high levels S Curve dimming is finer at low levels and high levels and coarser at medium levels Independently of the selected dimming curve you can also choose between smooth or fast dimming Color wheel A very complet...

Page 24: ...s equipment was received without a line cord plug attach the appropriate line cord plug according to the following code brown live blue neutral green yellow earth 2 In different countries the colors of the cores in the mains lead of this equipment may not correspond with the colored markings identifying the terminals in your plug proceed as follows 3 This equipment must be earthed 4 Equipment suit...

Reviews: