Apply pressure
to the indicated
face of the
extrusion
Release the
inner/outer edge
of the extrusion
over its entire
length
Lift the extrusion
out and away from
the wall posts
8
9
10
11
12
13
Carefully tear off the side wraps
and discard. Then remove the
extrusions as shown below.
Screw fixing position
(x3 per wall post)
Lateral Adjustment
(Anti-Clockwise to
expand)
Height adjustment
(Level bottom rail)
Position onto the tray
, Expand frame equally into the opening using
the x3 lateral adjustments on each wall post so that the frame wedges
into place. Level the bottom rail if required using the height adjustment.
Level the frame work to the wall and mark the screw fixing positions.
IF USING A SIDE PANEL PLEASE REFER
TO SIDE PANEL INSTRUCTIONS AFTER
THIS STAGE
TIP
TIP
To mark
the screw
fixing positions
dip the end of a
drill bit into some
shoe polish
Ensure the
framework is
level vertically
and horizontally
using a spirit level
CAREFULLY
REMOVE THE FRAME
FROM THE TRAY
1
1
2
2
3
3
Once the enclosure is removed
drill holes into the walls using a
7mm Drill Bit, CHECK FOR
PIPES AND CABLES
Insert wall plugs or fixings
suitable for your walls. Then
secure frame to wall using X6
No.8x30 PH screws supplied
Level door frame using
adjustments shown in stage 9,
ensure the wall posts are
straight and not bowed out in the
middle from over tightening the
middle adjustment screws.
200mm
Equal distance to
fixed panel hole
centres
Carefully
lift fixed glass
panel into the enclosure and
secure to fixed panel patches.
Make sure you have the 4mm Allen
key & inner patch covers to hand.
Ensure the rigid seal is to the wall
post with the Life Shield treated
surface to the inside.
Place fixed glass onto the bottom patches
and hold firm with your foot. Push the top
of glass onto locating holes in top patches
and re-fit the inner patch covers. Repeat
for the bottom patches.
Measure
the centres of the holes in the fixed panel, once done
position the patch closest to the wall post 200mm away from the
post, then space the second patch the equal distance from this to
the fixed panel holes (measure to the centre
of the fixed panel patches). Repeat for the
patches at the bottom.
Slide the fixed panel
up to the wall post,
slightly loosening the
allen key screws
may make this easier
Ensure the lip on
the rigid seal
locates into the
extrusion over it’s
full length
Using X4 6x20PH
screws secure the
patches into the pre
drilled holes, if the holes
do not line up loosen
the allen key screw and
move patch on glass to
align, re-tighten all allen
key screws.
Re-fit the extrusions
by reversing the procedure in stage “8" Slide
fixed panel back to the fixed side wall post, ensure lip of seal fully
locates into the groove in the extrusion. Once secured ensure all
allen screws are fully tightened.
Fixed panel glass
This rigid seal
on the edge of the
fixed panel glass
is to go to the
wall post with the
lip to the inside
Seal
IMPORTANT
Before fitting the fixed panel
glass, ensure that the Shim
Strip is placed between the
bottom rail and the tray half
way along it’s length, this will
support the weight of the
glass and prevent the bottom
rail bowing
SHIM
STRIP