2. Cleaning the air cleaner paper
element
Every 100 hours of operation or annually replace the
paper element.
Check the air cleaner daily or before starting the
engine. Check for a buildup of dirt and debris around
the air cleaner system. Keep this area clean. Also
check for loose or damaged components. Replace all
bent or damaged air cleaner components.
1. Lift up the tabs to open the air cleaner cover.
(1) Air cleaner cover
(A) “LIFT UP”
2. Remove the air cleaner paper element and the air
intake hose.
(1) Air cleaner cover
(2) Air cleaner paper element
(A) Air intake hose
(1) Air cleaner paper element
(A) Air intake hose
3. Clean the air cleaner base as required and check
condition.
(B) Air cleaner base
4. Reinstall the air cleaner paper element into the air
intake hose, and reinstall them in place.
5. Close the air cleaner cover.
NOTE :
• Operating the engine with loose or damaged
air cleaner components could allow
unfiltered air into the engine causing
premature wear and failure.
3. Cleaning engine shroud
WARNING
To avoid serious injury or death:
• Make sure the engine is cool to the touch before
removing shrouds.
• Always shield eyes and face from air deposits
and objects.
1. Remove the engine shroud mounting bolts and
detach the shroud.
EVERY 100 HOURS
PERIODIC SERVICE
Z231KW-AU
49
Summary of Contents for Z231KW-AU
Page 7: ...4 Z231KW AU ...
Page 13: ...SAFETY LABELS SAFE OPERATION 10 Z231KW AU ...
Page 14: ...SAFE OPERATION Z231KW AU 11 ...
Page 15: ...SAFE OPERATION 12 Z231KW AU ...
Page 16: ...SAFE OPERATION Z231KW AU 13 ...
Page 66: ... 1 Cutting height fine tuning bolt 2 Jam nut MOWER DECK LEVEL ADJUSTMENT Z231KW AU 63 ...