WARNING
To avoid serious injury or death:
• Batteries, battery posts, terminals and related
accessories contain lead, lead compounds and
other chemicals known to the State of California
to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
• Never remove the battery cap while the engine
is running.
• Keep electrolyte away from eyes, hands and
clothes. If you are spattered with electrolyte,
wash it away completely with water immediately
and get medical attention.
• Keep open sparks and flames away from the
battery at all times. Hydrogen gas mixed with
oxygen becomes very explosive.
• Wear eye protection and rubber gloves when
working around the battery.
NOTE :
• The factory-installed battery is a non-refillable
type.
If the battery is weak, charge the battery or
replace it with a new one.
IMPORTANT :
• Mishandling the battery shortens the service life
and adds to maintenance costs.
The original battery is maintenance free, but
needs some servicing.
If the battery is weak, the engine will be difficult
to start and the lights will be dim. It is important
to check the battery periodically.
• When exchanging an old battery with a new
one, use a battery of equal specifications (as
described in the following table).
Battery
type
Volts (V)
Reserve
capacity
(min)
Cold
cranking
amps
Normal
charging
rate (A)
U1-300
12
45
300
6.5
Regarding non-accessible maintenance-free type
batteries:
Maintenance-free,
non-accessible
batteries
are
designed to eliminate the need to add water. Yet the
volume of electrolyte above the plates may eventually
become depleted due to abnormal conditions such as
high heat or improper regulator settings. Use a
voltmeter to check the state of charge.
(See the following reference chart to determine if
charging is necessary.)
Battery voltage
Reference state of charge
12.6
100% (full charge)
12.4
75%
12.2
50%
12.0
25%
11.8
0%
6.1 Charging the battery
DANGER
To avoid serious injury or death:
• When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
WARNING
To avoid serious injury or death:
• When disconnecting the cable from the battery,
start with the negative terminal first. When
connecting the cable to the battery, start with
the positive terminal first.
• Never check the battery charge by placing a
metal object across the posts.
Use a voltmeter or hydrometer.
(1) Battery
(2) Ground cable
(+) Positive terminal
(-)
Negative terminal
1. To slow charge the battery, connect the battery
positive terminal to the charger positive terminal
and the negative to the negative. Then, charge for
at least 1 hour at 6.5 amperes.
2. A boost charge is only for emergencies. It will
partially charge the battery at a high rate and in a
short time. When using a boost-charged battery, it is
necessary to recharge the battery as early as
possible. Failure to do this will shorten the battery's
service life.
PERIODIC SERVICE
EVERY 100 HOURS
52
Z231KW-AU
Summary of Contents for Z231KW-AU
Page 7: ...4 Z231KW AU ...
Page 13: ...SAFETY LABELS SAFE OPERATION 10 Z231KW AU ...
Page 14: ...SAFE OPERATION Z231KW AU 11 ...
Page 15: ...SAFE OPERATION 12 Z231KW AU ...
Page 16: ...SAFE OPERATION Z231KW AU 13 ...
Page 66: ... 1 Cutting height fine tuning bolt 2 Jam nut MOWER DECK LEVEL ADJUSTMENT Z231KW AU 63 ...