Testing Open i ng Pressu re of Nozzle
1) Move the tester handle up and down to prime fuel.
Measure the pressure of fuel gushing out from the nozzle
tip.
2) If the measurement is not within the reference value,
adjust with the adjustment washer inside the nozzle
holder. (See page 76) An increase of every 0.1 mm
( 0.0039
in.) of washer thickness causes an approximate
980.6
kPa. ( 10 kgf/cm
2
,
142.2 lb./sq.in.) increase in fuel
injection pressure.
( Danger)
•
Be caref ul not to touch the injected fumes directly. On
touchi ng flesh, the f u mes destroy the organism. If it gets
i n the blood, it may cause blood poisoni ng.
,1 - otr:g -:-1
1990.8
to
2133.0 l b.ls
·
-
----··
55
CE,
Cleaning Air Cleaner Element
For a dry type element
1) How to clean by using compressed air:
Directly blow compressed air from inside to outside.
Pressure of compressed air must be under 205kPa
(2.1kgf/cm
2
,30psi).
2) How to clean by using solution:
Add 15 g
(0.03
lb.) Kubota genuine element detergent to
1 liter
(0.26
gal.) water. Let the element soak in the
solution for 15 minutes and then wash it well in the
solution. R inse well in clean water and dry.
0071 F001
01102-B
01302-B
01402-B
•
To remove d i rt and dust, use compressed air.
•
To remove carbon and grease, use solution.
V1502-B
V1702-B
V1902-B
0071F 002
3TLABAB1 P040A
Summary of Contents for D1102-B
Page 13: ...KiSC issued 09 2007 A 12...
Page 16: ...KiSC issued 09 2007 A 15...
Page 28: ...26 KiSC issued 09 2007 A...
Page 37: ...KiSC issued 09 2007 A 34...
Page 57: ...KiSC issued 09 2007 A 53...
Page 77: ...KiSC issued 09 2007 A 1...
Page 80: ...74 KiSC issued 09 2007 A...
Page 103: ...KiSC issued 09 2007 A Section V SERVICE DIRECTIONS Service Directions 98 Bolt Torques 102 97...