17
OPERATING THE ENGINE
B
Regeneration Operating Procedure
Operating Procedure for Regeneration Inhibit Mode
(1) Parked regeneration switch
(2) DPF INHIBIT switch
(3) Engine warning indicator
(4) Regeneration indicator
(5) Parked regeneration indicator
1.
Start the engine.
2.
Press the DPF INHIBIT switch
, and the switch lamp illuminates.
Switch lamp ON: Regeneration Inhibit Mode selected.
Switch lamp OFF: Auto Regeneration Mode selected.
3.
When the parked regeneration indicator
starts flashing:
A specific amount of PM has accumulated in the DPF muffler.
Move the tractor to a safe place and activates the DPF muffler. Follow the "Operating Procedure for Parked
Regeneration" procedure.