168
RG268-8135-6
01/2019
Maintenance
Remove the coolant expansion reservoir (1) and drain it, clean-
ing it if necessary. Refit the reservoir.
Mix the coolant.
The antifreeze strength must be between -25 °C and -40 °C.
Fill the premixed coolant into the radiator and expansion reservoir.
Close the expansion tank cover.
Close the radiator cap.
Start the engine and let it idle to warm up.
Stop the engine.
Check the coolant level, top up if necessary.
Close the side cover.
Close the engine compartment cover.
Dispose of old coolant according to the applicable en-
vironmental protection regulations.
Do not operate the cooling system with pure water
(even in summer). The antifreeze also contains a cor-
rosion inhibitor.
The antifreeze portion of the coolant should not ex-
ceed 50 %.
1
FULL
LOW
A
B