Kübler Group
5 Commissioning and Operation
HB Modbus Interface - R67048.0002 - 02
EN - 27
5.7.1.10 Register 13 Scaling Active State
Scaling values:
0 = scaling off
1 = scaling on
Estimated response delay for scaling: 10μs + response frame
processing time
Minimum cycle time for scaling update: 2ms
5.7.1.11 Registers 14 & 15 Serial Number
Permitted values:
Actual serial number in the following format:
0xYYDDDNNNNN
0xYY year (2 lst figures)
0xDDD day of the year (1...365)
Low word serial number 0xNNNNN consecutive number 1…65535
Response delay after SN update execution command:
15 ms (to be determined) required for the saving process
5.7.1.12 Register 16 Firmware
Saved values: Actual checksum of the firmware version
Default: 0xXXXX
Response delay after Firmware execution command: 200μs
5.7.2 Writing the Holding Register
5.7.2.1 Register 256 - 259 Write Communication Parameters
After a communication update, all communication parameters will be taken over only after com-
pletion of a switch off/switch on cycle. The new values are saved, but they will be taken over
only after a new switch-on cycle.
Singleturn parameters: 9600 bauds, 8 data bits, no parity, 1 stop bit
Multiturn parameters: 9600 bauds, 8 data bits, no parity, 2 stop bits
NOTICE
No parity
2 stop bits are necessary for the no parity and 115 kb setting.
The values are taken over with Execute communication parameters (Register 40261).
Response delay after Comm update execution command:
15 ms required for the saving process