Page 7 | ENG
Application area:
Pollution level 2
Insulation
Front side:
Double /
reinforced insulation
Relay:
Basic insulation
UL approval:
File no.: E128604
10.3 Mechanical data
Protection level:
IP65 (font side)
Weight:
appr. 80 g
10.4 Inputs
Inputs:
Reset, counting and key
lock inputs
Input polarity
(for reset and counting/start inputs):
12 ... 250 V AC/DC: bidirectional optocoupler
input
NPN:
NPN input activated by
transistor or contact
Key lock input:
is switched to +3 V DC
(terminal 1)
Min. input pulse duration:
Reset input:
50 ms
Key lock input:
15 ms
Input switching level:
12 ... 250 V AC/DC: LOW: < 1 V AC/DC
HIGH: 12...250 V AC/DC
NPN:
LOW: 0 ... 0,8 V DC
HIGH: 2.5 ... 30 V DC
Input frequency
Pulse counter:
max. 30 Hz
Time counter:
Measuring pulses
< 200 ms are not
measured accurately
Accuracy:
System error
+/- 100 ms per
measuring pulse
Time accuracy:
200 ppm
Input resistance:
110 kΩ
9. Interference suppression measures
The following interference suppression
measures may be required: if the output swit-
ches inductive loads (relays, solenid valves),
interferences must be suppressed by means of
a freewheeling diode for direct current and of
an RC element for alternating current. For safe
and EMC-compliant operation, use shielded
cables for the control inputs (counting, reset and
key lock inputs). The shield must be connected
at both ends. If this is not possible, a capacitor
(e.g. 10 nf) may be integrated on one side in the
shield connection.
10. Technical data
10.1 General technical data
Display:
2-line LCD display, each
with 6 decades 999999;
height 7 resp. 4,5 mm
Operating temperature: -20°C ... +65°C
(not condensing)
Storage temperature: -25°C ... +70°C
Altitude:
up to 2000 m
10.2 Electrical data
Voltage supply:
2 replaceable lithium
batteries type 1/2 AA
Lithium 3.6 V
Data backup:
min. 8 years for 5 x 10
6
output relay switching
cycles and 25°C opera-
ting temperature
EMC
Interference emission: EN 55011 Class B
Interference immunity: EN 61000-6-2,
EN 61326-1
Device safety
Designed to:
EN 61010
Protection class:
2 (front side)
Only the front side is classified as
accessible for the operator.