EN - page 22 (R60953.0009 3)
The following table shows the various states with respect to the safety circuit and to the door bypass
safety circuit.
Step
Description
Safety circuit
Door bypass
UCM
1
First commissioning
Open
Not possible
inactive
2
Touch top limit switch
Open
Not possible
inactive
3
Touch bottom limit switch
Open
Not possible
inactive
4
Set time-delayed limit switches Closed
Not possible
inactive
4
Teach every stop
Closed
Not possible
inactive
5
Actuate stops (by moving
again to the stops)
Closed
Not possible
inactive
6
Normal operation
Closed
Possible
active
As soon as all stops have been actuated, the PSU01 switches to the normal operating mode. More
detailed information on the parameters can be found in the programming manual or in the manual of a
compatible control or of the separately available programming unit.
6.3 Protected area parameterization
As delivered, the protected area (reduced shaft head / shaft pit) is always active. This means that both
inspection limit switches (top and bottom) are initially enabled (also wiring is required).
The inspection limit switches can be enabled/disabled selectively in configuration mode (see parame
-
terizing manual).
The possible options are described more in detail below:
Option Description
Protected area
Limited to
0.6 m/s
Bypassing for
inspection
0
No inspection limit switches,
inspection not wired
None
No
Possible*
1
Inspection limit switches top
and bottom, inspection wired
Top and bottom
Yes
Not possible
2
Inspection limit switch only
top, inspection wired
Only top
Yes
Not possible
3
Inspection limit switch only
bottom, inspection wired
Only bottom
Yes
Not possible
4
No inspection limit switches,
but inspection wired
None
Yes
Not possible
*Possible, as PSU01 receives no information about the inspection mode.