Description
6-digit multifunction LCD display
Easy-to-read 2-line LCD-display with annunciators
for both the displayed preset and the status of the
two outputs
Simultaneous display of the actual value and of the
presets or auxiliary counters
Versions with/without backlit display
Add./Sub. Preset counter with two presets
Relay or optocoupler outputs
Easy-to-program
Simple preset entry via the front keys or via the
Teach-In function
Step or tracking preset
Pulse, frequency, time or batch counter
Preset counter, Batch counter or Total Counter
(cumulative count)
Set function for pulse and time counter
Multiplication and division factor (00.0001 ..
99.9999) for pulse counter and frequency meter
Averaging and Start Delay for frequency meter
Input modes:
Pulse counter:
cnt.dir , up.dn , up.up , quad ,
quad2 , quad4 , A/B , (A-B)/Ax100%
Frequency meter:
A , A – B , A + B , quad , A/B ,
(A-B)/Ax100%
Timer:
FrErun , Auto , InpA.InpB , InpB.InpB
Output operations:
Add , Sub , AddAr, SubAr , AddBat , SubBat ,
AddTot , SubTot , Trail , TrailAr
4-stage RESET-Mode
3-stage keypad locking (Lock)
MPI input for Display Latch, Teach-In function or
Set function
Supply voltage 100 … 240 VAC ± 10%, 24 VAC or
10 .. 30 VDC
4
Display/Operating elements
T1-6 Decade key T1 … T6
P
Prog/Mode key
R Reset key
8
Current count value / main counter
9
Preset value/ Total count/ Batch counter
10 Run display for Timer
11 Shows which preset value is being displayed
12 Shows which preset output is active
Pr
Keys necessary for programming the
parameters (highlighted in grey)
5
Inputs
5.1
INP A, INP B
Signal inputs: function acc. to operating mode.
Max. frequency 60 kHz, can be damped in the
programming menu to 30 Hz.
Pulse counter:
Count inputs
Frequency meter:
Frequency inputs
Timer:
Start input or
Start/Stop inputs
5.2
RESET
Dynamic reset input: resets the pulse counter or
timer to zero (adding mode) or to preset value 2
(subtracting mode). The reset input can be inhibited
in the programming menu.
Pulse counter:
RESET input
Frequency meter:
no function
Timer:
RESET input
5.3
GATE
Static gate input: function depending on operating
mode.
Pulse counter:
no counting while active
Frequency meter:
no counting while active
Timer:
time measurement while
active(Gate.hi)
time measurement while
not active (Gate.Lo).
5.4
LOCK INPUT
Static keypad lock input for presets or
programming. Lock-out level can be set in the
programming menu.
5.5
MPI
Input. Programmable as Display Latch, Set or
Teach-In input.