10.11 Device safety
Design to:
EN 61010 Part 1
Protection Class:
Protection Class 2 (front side)
Only the front side is classified as accessible
for the operator.
Application area:
Pollution level 2
over-voltage Category II
Insulation:
Front: double insulation,
Rear side: basic insulation,
Signal inputs and und sensor power supply: SELV
10.12 Mechanical Data
Housing:
Panel-mount housing
to DIN 43 700, RAL 7021
Dimensions:
48 x 48 x 91 mm
Panel cut-out:
45
+0,6
x 45
+0,6
mm
Installation depth:
ca. 107 mm incl. terminals
Weight:
ca. 125 g
Protection:
IP65 (front, device only)
Housing material:
Polycarbonate UL94 V-2
Vibration resistance: 10 - 55 Hz / 1 mm / XYZ
(EN 60068-2-6):
30 min in each direction
Shock resistance:
EN 60068-2-27 100G / 2 ms / XYZ
3 times in each direction
EN 60068-2-29 10G / 6 ms / XYZ
2000 times in each direction
10.13 Connections
Supply voltage and outputs:
Plug-in screw terminal, 7-pin, RM5.08
Core cross section, max. 2.5 mm²
Signal and control inputs:
Plug-in screw terminal, 8-pin, RM 3.81
Core cross-section, max. 1.5 mm²
11 Scope of Delivery
Delivery includes
:
Preset counter
Mounting clip
Instruction manual
12 Ordering codes
6.924.X1XX.XX0
Input trigger levels
0 = Standard (HTL)
A = 4-30 VDC*
Supply voltage
0 = 100… 240 V AC ± 10%
2 = 24 VAC +/- 10%
3 = 10 .. 30 VDC
LCD version
0 = no backlighting
1 = green backlighting*
2 = LED Look*
3 = Multicolour
Outputs
0 = Relay
1 = Optocoupler*
Front
0 = Kübler version
A = Neutral version*
* 24 VAC power supply on request
13 Frequencies (typical)
13.1
Pulse counter
HTL level
AC supply
typ. Low
2,5 V
typ. High
22 V
DC supply 12V
typ. Low
2 V
typ. High
10 V
DC supply 24V
typ. Low
2,5 V
typ. High
22 V
Add
Sub
Trail
AddAr
SubAr
AddBat
SubBat
TrailAr
AddTot
SubTot
Cnt.Dir
55 kHz
2,8 kHz
2,7 kHz
Up.Dn
Up.Up
29 kHz
2,8 kHz
2,7 kHz
Quad
Quad 2
28 kHz
1,4 kHz
1,3 kHz
Quad 4
18 kHz
1,2 kHz
0,9 kHz
A/B
(A-B)/A
29 kHz
Page 20
www.kuebler.com