Lock input
When the Lock input is activated
the programming is inhibited.
When the Lock input is activated
the setting of the preset values is
inhibited.
When the Lock input is activated
the setting of the preset values
and the programming are both
inhibited.
7.8.6.2 Mainmenu for the output operations
Mainmenu for determining the
operation of the outputs
Count mode ADD
Outputs active when count status
> preset value
Reset to zero
Count mode SUBTRACT
Output 1 active when
count status < preset value 1
Output 2 active when
count status < 0
Reset to preset 2
Count mode ADDING with
automatic reset
Output 1 active when count
status > preset value 1
Output 2 (timed signal) active
when count status = preset value
2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic
reset
Output 1 active when count
status < preset value 1
Output 2 (timed signal) active
when count status = 0
Automatic reset to preset 2 when
count status = 0
Reset to preset 2
Count mode ADDING with
automatic reset and Batch
counter
Output 2 (timed output) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active when batch
counter > preset 1
manual reset sets both counters
to zero
electrical reset sets only main
counter to zero
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset 2 when
main counter = zero
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 active bei Batchzähler >
Preset 1
Manual reset sets main counters
to preset value 2 and batch
counter to zero
Electronic reset only sets the
main counter to preset value 2
Count mode ADDING with
automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Total counter counts all the count
pulses from the main counter
Output 1 active when total
counter > preset value 1
Manual Reset sets both counters
to zero
Electronic reset only sets the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Total
counter
Output 2 (timed signal) active
when main counter = zero
Automatic reset to preset value 2
when main counter = zero
Total counter counts (sub from
preset value 1) all count pulses
from main counter
Output 1 active when Total
counter < zero
Manual reset sets both counters
to the preset values
Electronic reset sets only main
counter to preset value 2
Page 14