www.kuebler.com
Page 21
55..55..11..44 A
Alla
arrm
m 11 H
Hyysstte
erre
essiiss
Here hysteresis means: The difference in
thresholds between switching on and
switching off. This difference should be
selected large enough to avoid undesired
switching actions at the output due to the
variations of the current instantaneous
value.
N
No
otte
e::
Alarm value and hysteresis are always
based on the displayed current value and
not on the input signal value.
FFo
orr p
po
ossiittiivve
e a
alla
arrm
m vva
allu
ue
e::
Switching on hysteresis
Switching off hysteresis
Positive
alarm
Output
Switching on value = alarm + switching on hysteresis
∆
a
Switching off value = alarm – switching off hysteresis
∆
b
The switching on value m
mu
usstt b
be
e g
grre
ea
atte
err than the switching off value.
FFo
orr n
ne
eg
ga
attiivve
e a
alla
arrm
m vva
allu
ue
e::
Switching on
hysteresis
Switching off
hysteresis
Negative
alarm
Output
Switching on value = alarm – switching on hysteresis
∆
a
Switching off value = alarm + switching off hysteresis
∆
b
The switching on absolute value (numerical value without sign)
m
mu
usstt b
be
e g
grre
ea
atte
err than the absolute value for switching off.
Current