Page 6
www.kuebler.com
D
Diig
giitta
all iin
np
pu
uttss
Input MPI*
Function of the inputs depending on set up
1. Function Display-Hold
to stop the instantaneous value
2. Function Reset
Reset the alarm value
Alarm Latch
3. Function Reset-Totalizer
Resetting the Totalizer
*MPI: Multi Purpose Input
Input KEY
Keypad lock-out of alarm settings
Switching level
logical 0
0 ... 2 V DC
logical 1
4 ... 30 V DC
Min. pulse duration
> 5 ms
Input MPI and Input KEY are galvanically isolated
22..22..33 O
Ou
uttp
pu
uttss
A
Alla
arrm
m 11//A
Alla
arrm
m o
ou
uttp
pu
utt 22
R
Re
ella
ayy o
ou
uttp
pu
utt with volt-free changeover contacts
can be setup as normally closed or normally open
Switching voltage
250 V AC/300 V DC
Switching current
max. 3 A AC/DC, min. 30 mA DC
Switching power
2000 VA / 50
Ω
o
orr NPN-o
op
ptto
oc
co
ou
up
plle
err with open collector and open emitter
Switching power
30 V DC/15 mA
U
CEsat
at Ic = 15 mA
max. 2.0 V DC
U
CEsat
at Ic = 5 mA
max. 0.4 V DC
A
Au
uxxiilliia
arryy p
po
ow
we
err ssu
up
pp
pllyy o
ou
uttp
pu
utt ffo
orr m
me
ea
assu
urriin
ng
g ttrra
an
nssd
du
uc
ce
err//sse
en
nsso
orr
A
AC
C models
voltage output 10 V DC ±2%, 30 mA
and
voltage output 24 V DC ±15%, 50 mA
D
DC
C models
only voltage output 10 V DC ±2%, 30 mA
The auxiliary power supply is galvanically isolated from the inputs, outputs and
the interface.
22..22..44 IIn
ntte
errffa
ac
ce
e
Available options
RS232, RS485, RS422
Baud rate
600, 1200, 2400, 4800, 9600, 19 200 programmable
Address
00 ... 99 programmable
Data format
8 Data bit, no parity, 1 stop bit
Character format
advanced ASCII character format of
IBM-PC without graphic characters
The interface is galvanically isolated from the inputs, outputs and auxiliary voltage.
Summary of Contents for CODIX 555
Page 2: ......