4 Installation
Kübler Group
40 - EN
BA Ants LES02 - R60073.0009 - 02
NOTICE
Coded band orientation and condition
Ensure proper coded band orientation. This is important for the good
operation of the sensor.
•
Important:
Also pay imperatively attention to the side orientation of
the holes. A marking showing the proper orientation can be found
on the type plate of the sensor.
• Do not remove the type plate at the beginning of the coded band,
which shows the "top end" for the installation orientation of the
coded band.
Coded bands without such label may not be used.
• Make sure during elevator downwards travel that there is no dirt or
foreign bodies on the coded band.
NOTICE
Coded band type plate (392 m)
If you prepare the 392 m coded band yourself, document the respect-
ive length on the follow-up form with a waterproof pen.
On the remaining coded tape, mark the new band start in the appro-
priate direction and the respective length with one of the provided
type plates
NOTICE
Safety assessment of the fastening
Design the fastening of the coded band in compliance with the safety
guidelines of the competent inspection authority. The mounting kits
offered by Kübler comply with these guidelines and meet the require-
ments of the directives mentioned in the declaration of conformity.
NOTICE
Observe the pretension of the coded band
The coded band requires a tension between 100 ...150 N, corres-
ponding to a spring extension of 45 ... 75 mm.
NOTICE
Use a securing element
Use a securing element in parallel with the spring.
This element must have a minimum breaking force of 8.3 kN
Summary of Contents for Ants LES02
Page 70: ...4 Installation K bler Group 70 FR BA Ants LES02 R60073 0009 02 27021597914791691...
Page 96: ...4 Installazione K bler Group 96 IT BA Ants LES02 R60073 0009 02 27021597914791691...
Page 122: ...4 Instalaci n K bler Group 122 ES BA Ants LES02 R60073 0009 02 27021597914791691...
Page 138: ...4 K bler Group 138 ZH CHS BA Ants LES02 R60073 0009 02 4 4 1 RMA 153 4 1 1...
Page 154: ...Step by Step Installation K bler Group 154 BA Ants LES02 R60073 0009 02 a b...
Page 155: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 155 c d...
Page 156: ...Step by Step Installation K bler Group 156 BA Ants LES02 R60073 0009 02 e f...
Page 157: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 157 g h...
Page 158: ...Step by Step Installation K bler Group 158 BA Ants LES02 R60073 0009 02 i j...
Page 159: ...K bler Group Notizen Notes...