Kübler Group
3 Product Description
English
BA Ants LES02 - R60073.0009 - 02
EN - 35
Electrical characteristics sensor
Supply voltage
10 … 30 V DC
Supply voltage according to UL 1310
Class 2
Supply voltage according to EN 60950
PELV
Current consumption
max. 100 mA
Protection class according to EN 61140 III
Safety data
Relevant Standards
EN 81-20:2014
EN 81-50:2014
Classification
SIL3
PFHd value
< 1 x 10
-8
h
-1
Service life
20 years
EMC
Relevant Standards
EN 12015:2014
EN 12016:2013
UL - Underwriters Laboratories
UL approval
File E498900
Relevant Standards
UL 508
CAN Characteristics
Protocol
Proprietary
Transmission interval
every 2 ms
Baud rate
250 kbits
Terminated
yes
Max. distance to an evaluation unit
100 m (CAN bus),
twisted pair 0.5 mm2, with shield
For further information, refer to the Ants LES02 CAN manual.
3.4.2 Coded Band
Material
V2A spring-tensioned stainless steel, edges broken
Dimensions
16 x 0.4 mm
Weight
50 g / m
Thermal expansion
16 x 10
-6
/ K
Summary of Contents for Ants LES02
Page 70: ...4 Installation K bler Group 70 FR BA Ants LES02 R60073 0009 02 27021597914791691...
Page 96: ...4 Installazione K bler Group 96 IT BA Ants LES02 R60073 0009 02 27021597914791691...
Page 122: ...4 Instalaci n K bler Group 122 ES BA Ants LES02 R60073 0009 02 27021597914791691...
Page 138: ...4 K bler Group 138 ZH CHS BA Ants LES02 R60073 0009 02 4 4 1 RMA 153 4 1 1...
Page 154: ...Step by Step Installation K bler Group 154 BA Ants LES02 R60073 0009 02 a b...
Page 155: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 155 c d...
Page 156: ...Step by Step Installation K bler Group 156 BA Ants LES02 R60073 0009 02 e f...
Page 157: ...K bler Group Step by Step Installation BA Ants LES02 R60073 0009 02 157 g h...
Page 158: ...Step by Step Installation K bler Group 158 BA Ants LES02 R60073 0009 02 i j...
Page 159: ...K bler Group Notizen Notes...