12
Counting unit: seconds (the setting of the
decimal point determines the resolution).
Counting unit: minutes (the setting of the
decimal point determines the resolution).
Counting unit: hours (the setting of the
decimal point determines the resolution).
Counting unit: hours:minutes:seconds
(the setting of the decimal point is
ignored).
5.2.6 Counting unit
5.2.5 Operation of the GATE input
Counting runs when the GATE input is
OFF.
Counting runs when the GATE input is
ON.
5.2.7 Decimal point setting
The decimal point determines the
number of decimal places displayed. It is
only used for displaying purposes and
has no influence on the counting.
0
no decimal place
0.0
one decimal place
0.00
two decimal places
0.000
three decimal places
Manual (using the red push-button) and
electrical resetting
No resetting possible (red push-button
and reset input idle)
Only electrical resetting
Only manual resetting
5.2.8 Resetting mode
5.2.11 End of programming
Programming is carried out once more.
The values input can be checked and
modified.
Programming is complete and the values
input are taken over as new parameters.
Then the device is ready for operation.
5.2.10 Duration of the timed signal of the output
(only
if a timed signal has been programmed in 5.2.9)
The duration can be set between 0.01 sec.
and 99.99 sec.
A 0.00 setting is not accepted
5.2.9 Shape of output signal
Permanent signal
of the output, activated
at count value
³
preset in adding mode
and at count value
£
0 in subtracting mode
Permanent signal
of the output, will
become passive at count value
³
preset
in adding mode and at count value
£
0 in
subtracting mode
Timed signal
of the output will become
passive at count value
³
preset in adding
mode and at count value
£
0 in subtracting
mode
Timed signal
of the output is activated at
count value
³
preset in adding mode and
at count value
£
0 in subtracting mode