BoWex
®
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
40110 EN
20 of 22
16
Please observe protection
note ISO 16016.
Drawn:
2019-07-01 Pz/Wb
Replacing:
KTR-N dated 2017-01-02
Verified:
2019-07-23 Pz
Replaced by:
The ATEX marking of the BoWex
®
curved-tooth gear coupling is applied on the outer sheath or on the front side.
For the complete marking refer to the operating/assembly instructions and/or the delivery note/package.
The following marking applies for the products:
•
Type M with standard sleeve (light), sizes M-14 and M-19
•
Type S..-St with standard sleeve (light), sizes S14-St to S24-St inclusive
•
Type M with conductive sleeve (black), sizes M-14C to M-80C inclusive
•
Type SSR with Seeger circlips with conductive sleeve (black),
sizes 24 SSR to 125 SSR inclusive
•
Type S..-St with conductive sleeve (black), sizes S14-St to S55-St inclusive
BoWex
®
<Year>
I M2 Ex h I
Mb
II 2G Ex h IIC T6
… T4
Gb
II 2D Ex h IIIC T80 °C
… T120 °C Db
-
30 °C ≤ T
a
≤ +60 °C … +100 °C
KTR Systems GmbH, Carl-Zeiss-Straße 25, D-48432 Rheine
•
Type M with standard sleeve (light), sizes M-24 to M-65 inclusive
•
Type SSR with Seeger circlips with standard sleeve (light), sizes 24 SSR to 45 SSR inclusive
•
Type S..-St with standard sleeve (light), sizes S28-St to S55-St inclusive
BoWex
®
<Year>
I M2 Ex h I
Mb
II 2G Ex h IIB
T6
… T4
Gb
II 2D Ex h IIIC T80 °C
… T120 °C Db
-
30 °C ≤ T
a
≤ +60 °C … +100 °C
KTR Systems GmbH, Carl-Zeiss-Straße 25, D-48432 Rheine
Short marking:
(A short marking is only made if not possible differently for reason of space or functioning.)
BoWex
®
<Year>
Deviating marking applies until 31st October 2019:
Short marking:
II 2GD c IIC T X/I M2 c X
Complete marking:
II 2G c IIC T6, T5 resp. T4
-30 °C
T
a
+65 °C, +80 °C resp. +100 °C
II 2D c T 120 °C -30 °C
T
a
+100 °C
I M2 c -30 °C
T
a
+100 °C
9
Enclosure A
Advice and instructions regarding the use in
potentially explosive atmospheres
9.5
marking of coupling for potentially explosive atmospheres