background image

 

 

 

 

KGC-320, KGC-320-HP

 

 

Web Smart 

Gigabit Ethernet Media Converter 

10/100/1000BASE-T to 100/1000BASE-X 

 

Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

DOC.120925 

-1- 

Summary of Contents for KGC-320

Page 1: ...KGC 320 KGC 320 HP Web Smart Gigabit Ethernet Media Converter 10 100 1000BASE T to 100 1000BASE X Installation Guide DOC 120925 1 ...

Page 2: ...es the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 269...

Page 3: ...ly approved by the party responsible for compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with CISPR Class A WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the us...

Page 4: ...7 Loop back Test Push Button 18 2 7 1 Pressing Button to Restore Factory Default Settings 18 2 8 Configuration DIP SW 19 2 9 LED Indication 20 2 10 Configuring IP Address and Password for the Device 21 3 Functions 22 3 1 Abbreviation 22 3 2 Converter Function 22 3 3 Link Fault Pass Through Function 23 3 4 Remote TP Status Monitoring Function 24 3 5 802 1Q Control Function 25 3 6 SNMP Support 26 4 ...

Page 5: ... IGMP Snooping 38 4 7 Storm Control 39 4 8 Statistics 40 4 9 Detailed Statistics 41 4 10 IGMP Status 42 4 11 Loopback Test 43 4 12 Reboot System 43 4 13 Restore Default 43 4 14 Update Firmware 44 4 15 Configuration File Transfer 45 4 16 Logout 45 Appendix A Factory Default Settings 46 ...

Page 6: ...esigned for accommodating Gigabit Ethernet 1000BASE X optical fiber transceiver and the other is designed for accommodating Fast Ethernet 100BASE FX optical fiber transceiver Each SFP can be installed with variety of optional transceivers supporting multimode or single mode fiber for short reach up to long reach distance Power over Ethernet support The copper port is featured Power over Ethernet P...

Page 7: ...removal Untagging Packet Tag insertion Tagging Quality of Service For conversion between two different speeds the device is featured with powerful Quality of Service QoS function which can classify the priority for received network frames based on the ingress port and frame contents Furthermore many service priority policies can be configured for egress operation Web Management The device is embed...

Page 8: ...g Diversified mounting support desktop wall and optional Din Rail support Support wide range of fiber options 1000BASE X rated 100BASE FX rated multimode fiber single mode fiber short reach up to long reach Bi directional single fiber and CWDM Management functions Port configuration control and status monitoring Support Jumbo frame conversion Packet filtering 802 1Q Control between two ports Quali...

Page 9: ...ce IEEE 802 3 1000BASE X mini GBIC Connectors SFP for optional SFP type Gigabit Ethernet fiber transceivers Configuration Auto Forced 1000Mbps Full duplex Transmission rate 1000Mbps Network cables MMF 50 125 60 125 SMF 9 125 Eye safety IEC 825 compliant Fast Ethernet SFP for Fiber Port Compliance IEEE 802 3 100BASE FX Connectors SFP for optional SFP type Gigabit Ethernet fiber transceivers Configu...

Page 10: ...t Ethernet SFP is selected for use Configuration DIP Switches SW1 SW3 Twisted pair copper port configuration SW4 Flow control setting SW5 Remote Twisted pair copper port monitoring SW6 Link fault pass through function setting Basic Functions MAC Addresses Support up to 8K Forwarding technology Store and forward Maximum packet length Jumbo frame support up to 9600 bytes Flow control IEEE 802 3x pau...

Page 11: ...perating Temperature Typical 10ºC 50ºC Storage Temperature 40ºC 85ºC Relative Humidity 10 90 Electrical Approvals FCC Part 15 rule Class A CE EMC CISPR22 Class A Software Management Functions Interfaces Web browser Management objects System configuration IP settings Name Password Port configuration control and status 802 1Q control settings QoS settings Reboot restore factory default Update firmwa...

Page 12: ...F 1310 8 2 23 1 20km LX30 LC SMF 1310 4 1 24 3 30km LX50 LC SMF 1550 4 1 24 3 50km LX70 LC SMF 1550 0 5 24 3 70km W3510 LC Bi Di SMF Tx 1310 Rx 1550 9 3 21 1 10km W5310 LC Bi Di SMF Tx 1550 Rx 1310 9 3 21 1 10km W3520 LC Bi Di SMF Tx 1310 Rx 1550 8 2 23 1 20km W5320 LC Bi Di SMF Tx 1550 Rx 1310 8 2 23 1 20km Model Ext 100M Fiber Wavelength nm Tx Power dBm Sensitivity dBm Rx Max dBm Distance M LC M...

Page 13: ...r unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings...

Page 14: ...eat dissipation from and adequate ventilation around the device Do not place heavy objects on the device Wall mounting The device has one mounting wall on the bottom side to support wall mounting Din Rail mounting For a Din Rail chassis the device can support mounting on a Din Rail An optional Din Rail mounting kit can be purchased separately as shown below 14 ...

Page 15: ...pecifications Rated input voltage 100 240 VAC Rated input frequency 50 60Hz Output voltage 56VDC 1 3 Output current 1 16A max Power cord De attachable IEC320 AC power cord Steps to apply the power to the device are 1 Connect power adapter DC plug to the DC input jack located on the back of the unit before connecting to the AC outlet 2 Connect the power adapter to the AC outlet 3 Check Power LED in...

Page 16: ... link is being established If the connected device is also auto negotiation capable both devices will come out the best configuration after negotiation process If the connected device is incapable in auto negotiation the port will sense the speed and use half duplex for the connection Port Configuration Management For making proper connection to an auto negotiation INCAPABLE device it is suggested...

Page 17: ...connector before making cable connection The following figure illustrates a connection example between two fiber ports Make sure the RX to TX connection rule is followed on the both ends of the fiber cable Network Cables Multimode MMF 50 125 62 5 125 Single mode SMF 9 125 Fiber Port Configuration Three modes are available for fiber port configuration Auto GE preference Auto selection GE SFP GE_SFP...

Page 18: ...during installation and check the test result displayed on the LED indicators 2 7 1 Pressing Button to Restore Factory Default Settings The button may also be used to restore the software configuration settings to factory default values The operations are Operations Functions Press the button and release in normal operation Perform loop back test over fiber cable Press the button about 5 seconds w...

Page 19: ...P Port in non auto 10Mbps Half duplex mode ON ON OFF Set TP Port in non auto 100Mbps Full duplex mode OFF OFF ON Set TP Port in non auto 100Mbps Half duplex mode ON OFF ON Set TP Port in auto 1000Mbps Full duplex mode OFF ON ON Disable TP Port function ON ON ON Set TP Port in auto 10 100 1000M Half Full duplex OFF Enable flow control ON Disable flow control OFF Disable remote TP status auto report...

Page 20: ... for 10 seconds to indicate a test result is displayed on LBR ON Loop back Test OK LBR Loop back test result 3 Blink Loop back Test failed 3 LBR display is valid only when LBT is ON LBR is displayed for 10 seconds to indicate a loop back test result ON 1000M link is established on TP port TP1G TP 1000M link status OFF TP port link is down ON 100M link is established on TP port TP100 TP 100M link s...

Page 21: ...etwork Each unit should be designated a new and unique IP address in the network Refer to Web management interface for System Configuration The managed device is shipped with factory default password 123 for software management The password is used for authentication in accessing to the device via web based interface For security reason it is recommended to change the default settings for the devi...

Page 22: ...ld TPID User priority CFI VID TPID 16 bit field is set to 0x8100 to identify a frame as an IEEE 802 1Q tagged packet User Priority 3 bit field refer to the 802 1p priority CFI The Canonical Format Indicator for the MAC address is a 1 bit field VID VLAN identifier 12 bit field identifies the VLAN to which the frame belongs to Untagged packet A standard Ethernet frame with no VLAN Tag field Priority...

Page 23: ...he link fault is forwarded to both Gigabit link partners finally by LFPT operation of two media converters Both Gigabit devices will also detect a link fault on each Cat 5 connection although the real fault occurs on the fiber connection exactly The following example illustrates a real link fault occurs on one Cat 5 and the link fault is passed to the other Cat 5 over two converters and the fiber ...

Page 24: ...er cable The status is displayed on the local LED indicators as follows Methods to enable the function Hardware setting DIP SW5 is set to ON position Software setting Web management Configuration System Remote TP auto report Remote TP Status Display 1 The status is displayed on local LEDs i e TP1G TP100 TP10 TPFDX when LTP is OFF LED State Status LTP OFF Remote TP status is valid on the following ...

Page 25: ...sm to filter all incoming untagged packets or to filter all incoming VLAN tagged packets The options are Disable Disable port ingress drop function Untag Only All incoming untagged packets and priority tagged packets are dropped Only VLAN tagged packets are admitted Tag Only All incoming VLAN tagged packets are dropped Only untagged packets and priority tagged packets are admitted Ingress Keep Tag...

Page 26: ...ult Tag VID Default Tag CFI Default Tag Priority settings These settings compose one ingress port Default Tag This tag is used when a tag insertion is required for untagged packets 802 1Q Filtering 802 1Q VID Filtering function allows to admit or reject certain VID tagged packets Up to 16 allowed positive list or rejected negative list VIDs can be configured This function allows to limit certain p...

Page 27: ...rmation Base for network management of TCP IP based internets MIB II RFC 1493 Definitions of Managed Objects for Bridges RFC 2863 The Interfaces Group MIB RFC 1573 Evolution of the Interfaces Group of MIB II SNMP Trap Support TRAP_COLDSTART the device boot up trap TRAP_LINKUP the port link recovery trap TRAP_LINKDOWN the port link down trap SNMP Settings The settings are used to configure SNMP fun...

Page 28: ...ice boot up TP copper port link down TP copper port link up link recovery FX fiber port link down FX fiber port link up link recovery Example of SNMP Trap Event The following example illustrates an event of FX port link down occurs and is detected by the device Then it generates a trap message to the SNMP trap host PC 28 ...

Page 29: ...anaged from web browser software make sure a unique IP address is configured for the unit 4 1 Start Browser Software and Making Connection Start your browser software and enter the IP address of the unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http xxx xxx xxx xxx Factory default IP address 192 168 0 2 4 2 Login to the Device Uni...

Page 30: ...em Configuration is displayed after a successful login 4 3 Main Management Menu The following information describes the basic functions of the main menu Configuration System Device information system and IP related settings Ports Port link status operation mode configuration and other per port settings IGMP Snooping IGMP snooping related configuration Storm Control Packet Storm protection control ...

Page 31: ...est on fiber link Reboot System Command to reboot the device unit Restore Default Command to restore the device unit with factory default settings Update Firmware Command to update the device firmware Configuration File Command to transfer upload download configuration file Transfer Logout Command to logout from current web management 4 4 System 31 ...

Page 32: ...hardware version currently operating Active IP Address Currently used IP address for the switch management Active Subnet Mask Currently used subnet mask for IP address for the switch management Active Gateway Currently used gateway IP address for the switch management DHCP Server Current IP address of the DHCP server Lease Time Left The time left for the lease IP address currently used 32 ...

Page 33: ...ger SNMP Read community The community allowed for the SNMP get message SNMP Write community The community allowed for the SNMP set message SNMP Trap community The community used for the SNMP trap messages sent by the switch 802 1Q Control 802 1Q Control function main configuration Disable all packets are allowed to pass with no 802 1Q control Enable 802 1Q control mechanism is activated for the co...

Page 34: ...nt VLAN VID and replies tagged packets with tag composed of Management VLAN VID CFI and User Priority settings to the management host Summary of the rules 802 1Q Control Management VLAN VID Embedded Http Web Server operation Disabled Ignore Accept untagged web packets Reply untagged packets Enabled VID 0 Accept untagged web packets Reply untagged packets Enabled VID 0 Accept matched tagged web pac...

Page 35: ...uration Function Port UTP Twisted Pair copper port SFP Fiber port Link Port link status Speed and duplex status with green background port is link on Down with red background port is link down Mode Select port operating mode Disabled disable the port operation UTP Mode Auto negotiation Speed capability Duplex capability Disable Disable port operation Auto Enable 10 100 1000M Full Half 10 Half Disa...

Page 36: ...the page Any changes made locally will be undone 802 1Q Control Function Ingress Drop Disable disable port ingress drop and admit all packet types Untag Only Drop both untagged and priority tagged packets Tag Only Drop VLAN tagged packets VID 0 Ingress Keep Tag Tag is removed from the received packet if it exists Enable set to activate tag removal for VLAN tagged packets Disable set to disable tag...

Page 37: ...ID table up to 16 VIDs can be configured in VID table VID 1 4095 decimal 12 bit VID value Apply Click to apply the changes Refresh Click to refresh the page Any changes made locally will be undone Back Click to go back to previous page Notes 1 VID table is referred for filtering VLAN tagged packets according to the VID value embedded in the packet For untagged or priority tagged packet Default Tag...

Page 38: ...nnected and require being forwarding IPMC packets unconditionally Unregistered IPMC Check to drop all unregistered IPMC packets Flooding enabled VLAN ID List of current existing VLANs IGMP Snooping Enabled Check to enable IGMP snooping on the associated VLAN IGMP Querying Enabled Check to enable IGMP querying on the associated VLAN Apply Click to apply the changes Refresh Click to refresh the page...

Page 39: ...ded Unicast Rate The rate limit of the flooded unicast packets transmitted on a port The flooded unicast packets are those unicast packets whose destination address is not learned in the MAC address table Apply Click to apply the changes Refresh Click to refresh the page Any changes made locally will be undone Notes 1 The unit of the rates is pps packets per second 2 No Limit no protection control...

Page 40: ...nk down Tx Bytes Total of bytes transmitted on the port Tx Frames Total of packet frames transmitted on the port Rx Bytes Total of bytes received on the port Rx Frames Total of packet frames received on the port Tx Errors Total of error packet frames transmitted on the port Rx Errors Total of error packet frames received on the port Apply Click to reset all statistic counters Refresh Click to refr...

Page 41: ... Description UTP Click to display all statistic counters of UTP port SFP Click to display all statistic counters of Fiber port Clear Click to reset all statistic counters Refresh Click to refresh the displayed statistic counters 41 ...

Page 42: ...f Received Queries V1 Reports The number of Received V1 Reports V2 Reports The number of Received V2 Reports V3 Reports The number of Received V3 Reports V2 Leave The number of Received V2 Leave Refresh Click to refresh the page Group Member Status Description VLAN ID The VLAN where the groups found Groups IPMC group IP found on the VLAN Port Members Port members found of the group 1 UTP port 2 Fi...

Page 43: ...lt message displayed after a test finished is The test result is also displayed on LEDs LBT and LBR 4 12 Reboot System This menu is used to reboot the device unit remotely with current configuration Starting this menu will make your current http connection lost You must rebuild the connection to perform any management operation to the unit 4 13 Restore Default 43 ...

Page 44: ...ake your current http connection lost 4 14 Update Firmware This menu is used to perform in band firmware software upgrade Enter the path and file name of new firmware image file for uploading Configuration Description Filename Path and filename warp format Browser Click to browse your computer file system for the firmware image file Upload Click to start upload 44 ...

Page 45: ...le to be uploaded Browse Click to browse your computer file system for the configuration file Upload Click to start upload operation from the connected PC to the switch Download Click to start download operation from the switch to the connected PC 4 16 Logout This menu is used to perform a logout from the web management If current user does not perform any management operation over 3 minutes the d...

Page 46: ...0 2 Fallback IP Subnet mask 255 255 255 0 Fallback Gateway IP 192 168 0 1 Management VLAN VID 0 Management VLAN CFI 0 ManagementVLAN Userpriority 0 Name Null Password 123 Inactivity Timeout secs 300 SNMP enabled Not select disabled SNMP Trap destination 0 0 0 0 SNMP Read community public SNMP Write community private SNMP Trap community public 802 1Q Control Disable QoS Control Disable Jumbo Mode D...

Page 47: ...le for PoE model Ingress Drop Disable Ingress Keep Tag Enable Egress Insert Tag Disable DefaultTag VID PVID 1 Default Tag CFI 0 Default Tag Priority 0 802 1Q Filtering Configuration VID TABLE Disable VID n n 1 16 0 ...

Reviews: