CHARACTERISTICS OF INPUT LOGICS
Balancing
Diagram
NC
NA
DBIL
Each CP board is having 4 PGM inputs with different balancing method:
NC (normally closed),
NO (normally open)
DBL (double-balancing or 2 EOL end-of-line)
It’s possible to direct link shutter sensors or inertial (glass-break)
The Control Panel manage the following options for each input:
• 24h (always active)
• immediate
• entrance delayed
• exit delayed
• Auto-bypass
• doorbell
ALL.
i
ALL.
i
Sab
.
i
ALL.
10kΩ
10kΩ
OUTPUT SECTION
The CP board have 2 OC outputs of 500mA each, all programmable as wished:
polarities (normally open or normally closed), functions (bistable or monostable), activation times (ON time).
POWER SUPPLY CONTROL
The lares Panel controls both the supply voltage and the battery voltage. It verifies periodically the
Battery Efficiency and send events in case of faults. Furthermore, in case of prolonged supply absence,
command the Detach Battery Function to prevent deep discharges: it is not just a simple protection,
but the Panel itself which auto switch-off and detach the Battery.
The CP executes all necessary controls, memorize date and moment of the switch-off for any further in-
vestigation and then makes a complete swicht-off immune from any inconvenience. In this case, even
the present Sirens will not sound to avoid useless disturbances.
+P
O
12V
6W max