9 Related Documents
62 of 72
Vitachrom
Double mechanical seal in tandem arrangement
412.02
922
103
230
163
24A
433.01
a)
b)
411.05
433.02
Fig. 16:
Double mechanical seal a) with O-ring (size group I) b) with V-ring (size group II)
Part No.
Description
Part No.
Description
103
Circular casing
412.03
O-ring
19)
163
Discharge cover
433.01
Mechanical seal (inboard)
210
Shaft
433.02
Mechanical seal (outboard)
230
Impeller
922
Impeller nut
411.05
V-ring
21)
24A
Quench liquid outlet (G1/8
20)
)
412.02
O-ring
24E
Quench liquid inlet (G1/8
20)
)
Supply systems for mechanical seals in tandem arrangement:
(
ð
Section 9.1.4, Page 63)
Anti-rotation device
163.02
562
b)
163.02
a)
Fig. 17:
Single or double mechanical seal a) without anti-rotation device, b) with anti-
rotation device
Part No.
Description
Part No.
Description
163.02
Discharge cover
562
Parallel pin of anti-rotation device