5 Installation at Site
22 of 72
Vitachrom
5 Installation at Site
5.1 Checks to be carried out prior to installation
Place of installation
WARNING
Installation on mounting surface which is unsecured and cannot support the load
Personal injury and damage to property!
▷
Use a concrete of compressive strength class C12/15 which meets the
requirements of exposure class XC1 to EN 206-1.
▷
The mounting surface must be set, flat, and level.
▷
Observe the weights indicated.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
5.2 Installing the pump set
DANGER
Static charging due to insufficient potential equalisation
Explosion hazard!
▷
Make sure that the connection between pump and baseplate is electrically
conductive.
CAUTION
Ingress of leakage into the motor
Damage to the pump!
▷
Never install the pump set with the "motor below".
Fastening Table 9:
Types of fastening
Motor size
Type of fastening
Up to 112 M
Angle foot
All motor sizes
Motor feet
All motor sizes
Ball feet
NOTE
For installation on motor feet of motor sizes 132 or 160, the motor feet must be
shimmed (20 mm shim height).
5.2.1 Removing the transport lock
Removing the transport lock
Removing the foam insert
ü
Delivery of pump without motor
1. Suspend or support the back pull-out unit to prevent it from tipping over.
2. Undo hexagon nut 920.02 and hexagon head bolt 901.02 at pump casing 103.
3. Remove discharge cover 163 and set it aside.
4. Pull the back pull-out unit out of the pump casing and place it on a clean, level
surface.
5. Remove the foam insert from the pump casing.