5 Installation at Site
25 of 72
Vitachrom
3. If required, install a filter in the piping (see drawing: Filter in the piping).
1
2
Fig. 7:
Filter in the piping
1
Differential pressure gauge
2
Filter
NOTE
Use a filter with laid-in wire mesh (mesh width 0.5 mm, wire diameter 0.25 mm) of
corrosion-resistant material.
Use a filter with a filter area three times the cross-section of the piping.
Conical filters have proved suitable.
4. Connect the pump nozzles to the piping.
CAUTION
Aggressive flushing liquid and pickling agent
Damage to the pump!
▷
Match the cleaning operation mode and duration of flushing and pickling to
the casing materials and seal materials used.
5.3.2 Permissible forces and moments at the pump nozzles
No piping-induced forces and moments (from warped pipelines or thermal
expansion, for example) must act on the pump.
The discharge and suction-side pipes must be anchored in such a way that no forces
and moments may act on the discharge and suction nozzle of the pump casing.
Otherwise, there is a risk of the impeller rubbing against the pump casing on the
suction-side, due to the narrow clearance between the impeller and the suction-side
floor of the pump casing.
5.3.3 Vacuum balance line
NOTE
Where fluid has to be pumped out of a vessel under vacuum, installing a vacuum
balance line is recommended.
The following rules apply to vacuum balance lines:
▪
Minimum nominal line diameter 25 mm.
▪
The line extends above the highest permissible fluid level in the vessel.
Summary of Contents for Vitachrom