5 Installation at Site
27 of 72
Vitachrom
Suitable fittings are available as accessories. When mounting the fittings comply with
the instructions provided by the fitting manufacturers.
NOTE
The flushing liquid feed line must be laid with a continuously rising slope towards
the flushing liquid reservoir.
Arrangement
Fit the quench reservoir (available as accessory) in the immediate vicinity of the pump
set approximately one metre above the pump centreline.
Fluid circulation is ensured by thermosyphon effect or forced circulation.
5.4 Enclosure/insulation
DANGER
Risk of potentially explosive atmosphere due to insufficient venting
Explosion hazard!
▷
Make sure the space between the casing cover/discharge cover and the bearing
cover is sufficiently vented.
▷
Never close or cover the perforation of the bearing bracket guards (e.g. by
insulation).
WARNING
The volute casing and casing/discharge cover take on the same temperature as the
fluid handled
Risk of burns!
▷
Insulate the volute casing.
▷
Fit protective equipment.
CAUTION
Heat build-up in the bearing bracket
Damage to the bearing!
▷
Never insulate the bearing bracket, bearing bracket lantern and casing cover.
5.5 Electrical connection
DANGER
Electrical connection work by unqualified personnel
Risk of fatal injury due to electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof models, EN 60079.
WARNING
Incorrect connection to the mains
Damage to the mains network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
1. Check the available mains voltage against the data on the motor name plate.
2. Select an appropriate starting method.
Summary of Contents for Vitachrom