The operator ensures that maintenance, inspection and installation are performed by
authorised, qualified specialist personnel who are thoroughly familiar with the
manual.
▪
Observe the safety instructions and information.
▪
For any work on the pump (set) observe the operating manual of the pump (set).
▪
In the event of damage you can always contact KSB Service .
▪
A regular maintenance schedule will help avoid expensive repairs and contribute
to trouble-free, reliable operation with a minimum of maintenance expenditure
and work.
▪
Never use force when dismantling and reassembling the equipment.
8.2 Servicing/Inspection
8.2.1 Supervision of operation
CAUTION
Increased wear due to dry running
Damage to the pump set!
▷
Never operate the pump set without liquid fill.
▷
Never close the shut-off element in the suction line and/or supply line during
pump operation.
CAUTION
Impermissibly high temperature of fluid handled
Damage to the pump!
▷
Prolonged operation against a closed shut-off element is not permitted
(heating up of the fluid).
▷
Observe the temperature limits in the data sheet and in the section on
operating limits.
While the pump is in operation, observe and check the following:
▪
If activated, check the functional check run.
▪
Measure the actual start-up pressure and stop pressure of the pump sets with a
pressure gauge. Compare the values with the specifications on the name plate.
▪
Compare the pre-charge pressure of the accumulator with the recommended
data. (
▪
Check the rolling element bearings for running noises.
Vibrations, noise and an increase in current input occurring during unchanged
operating conditions indicate wear.
▪
Monitor the functions of auxiliary connections, if any.
8.2.2 Maintenance schedule
Table 12:
Overview of maintenance work
Maintenance interval
Servicing/maintenance work
At least once a year
Check the pump and drive for smooth running and the mechanical seal for integrity.
Check the shut-off elements, drain valves and check valves for proper functioning and
tightness.
If fitted, clean the strainer in the pressure reducer.
If fitted, check the expansion joints for any wear.
Verify the pre-charge pressure. Check the accumulator for integrity.
(